The paper describes a new compact neutron spectrometer optimized for the detection of 2.5 MeV neutrons for fusion plasma applications. The first neutron spectroscopy measurements on a nuclear fusion plasma experiment (EAST) with this detector are also reported together with the data interpretation. The detector allowed separating the different neutron emission components from the plasma and to validate the effectiveness of the Neutral Beam Injection (NBI) heating. A possible improvement of the diagnostic has been also identified in order to increase the detector sensitivity to weak components of the neutron spectrum, such as those due to the Ion Cyclotron Resonace Heating (ICRH). The relatively simple response function of the (CLYC)-L-7 detector to 2.5 MeV neutrons together with its good capability in the n/gamma discrimination, makes this detector an interesting spectrometer for deuterium (D) plasma diagnostics. In particular, its compactness allows for integration in a multi-line of sight camera where space constraints are present.

First neutron spectroscopy measurements with a compact C7LYC based detector at EAST / D. Rigamonti, G.Q. Zhong, G. Croci, L. Giacomelli, G. Gorini, Z. Hu, A. Muraro, M. Nocente, E. Perelli Cippo, M. Rebai, M. Tardocchi, F. Camera, C. Cattadori, R.J. Zhou, L.Q. Hu, L. Ge, Y. Zhang, T.S. Fan. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 14:9(2019), pp. C09025.1-C09025.9. [10.1088/1748-0221/14/09/C09025]

First neutron spectroscopy measurements with a compact C7LYC based detector at EAST

F. Camera;
2019

Abstract

The paper describes a new compact neutron spectrometer optimized for the detection of 2.5 MeV neutrons for fusion plasma applications. The first neutron spectroscopy measurements on a nuclear fusion plasma experiment (EAST) with this detector are also reported together with the data interpretation. The detector allowed separating the different neutron emission components from the plasma and to validate the effectiveness of the Neutral Beam Injection (NBI) heating. A possible improvement of the diagnostic has been also identified in order to increase the detector sensitivity to weak components of the neutron spectrum, such as those due to the Ion Cyclotron Resonace Heating (ICRH). The relatively simple response function of the (CLYC)-L-7 detector to 2.5 MeV neutrons together with its good capability in the n/gamma discrimination, makes this detector an interesting spectrometer for deuterium (D) plasma diagnostics. In particular, its compactness allows for integration in a multi-line of sight camera where space constraints are present.
Neutron detectors (cold, thermal, fast neutrons); Nuclear instruments and methods for hot plasma diagnostics; Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators
Settore FIS/04 - Fisica Nucleare e Subnucleare
2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
Rigamonti_2019_J._Inst._14_C09025.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 644.65 kB
Formato Adobe PDF
644.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/680460
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 20
social impact