The main barrier to the wide use of maximal accumulated oxygen deficit (MAOD) is the considerable time required to apply several sub- and supra-maximal exercise sessions. The main question of this study was whether the determination of MAOD using a single supramaximal exercise session (MAODALT) is valid and reliable in running. We investigated the effects of the supramaximal exercise intensity (A) and the reliability of a single supramaximal exercise session (B) to assess MAOD in treadmill running. For this aim 29 subjects participated in A & B studies with single allocation "A" (n=15) and "B" (n=14). The conventional MAOD and 8 MAODALT were determined in exhaustive efforts varying between 100-150% at an intensity associated with maximal oxygen uptake (i+V˙O2MAX). In B study 2 supramaximal efforts were applied to analyze the test-retest reliability. Non-significant differences were found between MAOD and the 8 values of MAODALT. Despite the MAOD being statistically correlated with the MAODALT 100% i+V˙O2MAX (0.490.59), MAODALT determined at 115% of i+V˙O2MAX (52.4±1.7 mL·kg(-1)) presented the higher correlation values (0.650.77) and concordance. In addition, the MAOD at 115% of i+V˙O2MAX presented high test-retest reliability. MAODALT determined at 115% of i+V˙O2MAX was a valid and reliable method to assess MAOD in running.

MAOD Determined in a Single Supramaximal Test: a Study on the Reliability and Effects of Supramaximal Intensities / A.M. Zagatto, R. Bertuzzi, W.E. Miyagi, J. Padulo, M. Papoti. - In: INTERNATIONAL JOURNAL OF SPORTS MEDICINE. - ISSN 1439-3964. - 37:9(2016 Aug), pp. 700-707. [10.1055/s-0042-104413]

MAOD Determined in a Single Supramaximal Test: a Study on the Reliability and Effects of Supramaximal Intensities

J. Padulo
Penultimo
Methodology
;
2016

Abstract

The main barrier to the wide use of maximal accumulated oxygen deficit (MAOD) is the considerable time required to apply several sub- and supra-maximal exercise sessions. The main question of this study was whether the determination of MAOD using a single supramaximal exercise session (MAODALT) is valid and reliable in running. We investigated the effects of the supramaximal exercise intensity (A) and the reliability of a single supramaximal exercise session (B) to assess MAOD in treadmill running. For this aim 29 subjects participated in A & B studies with single allocation "A" (n=15) and "B" (n=14). The conventional MAOD and 8 MAODALT were determined in exhaustive efforts varying between 100-150% at an intensity associated with maximal oxygen uptake (i+V˙O2MAX). In B study 2 supramaximal efforts were applied to analyze the test-retest reliability. Non-significant differences were found between MAOD and the 8 values of MAODALT. Despite the MAOD being statistically correlated with the MAODALT 100% i+V˙O2MAX (0.490.59), MAODALT determined at 115% of i+V˙O2MAX (52.4±1.7 mL·kg(-1)) presented the higher correlation values (0.650.77) and concordance. In addition, the MAOD at 115% of i+V˙O2MAX presented high test-retest reliability. MAODALT determined at 115% of i+V˙O2MAX was a valid and reliable method to assess MAOD in running.
blood lactate concentration; glycolytic metabolic pathway; phosphagen metabolic pathway; supramaximal efforts
Settore M-EDF/02 - Metodi e Didattiche delle Attivita' Sportive
ago-2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
Zagato IJSM 2016 MAOD determined in a single supramaximal test a study on the reliability and effects of supramaximal intensities.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 636.68 kB
Formato Adobe PDF
636.68 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/670817
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact