Magnetic resonance imaging (MRI) has presented to anesthesiologists as unique challenge in patient monitoring because of its construction and principles of operation. Ferromagnetic materials within or near the scanner can distort the magnetic field, and monitoring wires act as antennae and this may result in image degradation. Nevertheless, monitoring is mandatory during MRI, especially in a child sedated or in general anesthesia. A monitoring system, made up of commercially available components, was assessed, and its effects on MR (1.5 tesla unit) image quality system determined. Variables monitored included: electrocardiogram and heart rate, (Sirecust 404, ECG cable set MR; Siemens, Enlanger, West Germany); blood pressure via automated sphygmomanometry (Press Mate BP-8800; Colin, Komaki, Japan); and continuous arterial saturation via pulse oximetry (Nellcor 100 E; Nellcor, Inc., Haywood, California). Fluid infusion rate was controlled by means of a plastic deliver (Dial-a-flo; Abbott Labs., Chicago, Illinois). Body temperature was maintained with a heat insulator blanket (Thermadrape, OR Concepts, Inc., Dallas, Texas). The monitoring technique described did not interfere with MRI function or produce image degradation.

Il monitoraggio del paziente pediatrico in corso di risonanza magnetica con un magnete superconduttore / C. Tommasino, L. Beretta, S. Cozzi, G. Paolillo, G. Torri. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - 57:1-2(1991), pp. 7-11.

Il monitoraggio del paziente pediatrico in corso di risonanza magnetica con un magnete superconduttore

C. Tommasino
Primo
;
S. Cozzi;G. Torri
1991

Abstract

Magnetic resonance imaging (MRI) has presented to anesthesiologists as unique challenge in patient monitoring because of its construction and principles of operation. Ferromagnetic materials within or near the scanner can distort the magnetic field, and monitoring wires act as antennae and this may result in image degradation. Nevertheless, monitoring is mandatory during MRI, especially in a child sedated or in general anesthesia. A monitoring system, made up of commercially available components, was assessed, and its effects on MR (1.5 tesla unit) image quality system determined. Variables monitored included: electrocardiogram and heart rate, (Sirecust 404, ECG cable set MR; Siemens, Enlanger, West Germany); blood pressure via automated sphygmomanometry (Press Mate BP-8800; Colin, Komaki, Japan); and continuous arterial saturation via pulse oximetry (Nellcor 100 E; Nellcor, Inc., Haywood, California). Fluid infusion rate was controlled by means of a plastic deliver (Dial-a-flo; Abbott Labs., Chicago, Illinois). Body temperature was maintained with a heat insulator blanket (Thermadrape, OR Concepts, Inc., Dallas, Texas). The monitoring technique described did not interfere with MRI function or produce image degradation.
Anesthesia; Child; Child, Preschool; Humans; Infant; Magnetic Resonance Imaging; Magnetics; Monitoring, Physiologic
Settore MED/41 - Anestesiologia
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

Caricamento pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/2434/670318
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact