Hydrodynamic performance of stented bioprostheses is far below that of the native valve. One of the reasons is that the internal diameter of the prosthesis is usually smaller than that of the native valve. However, other valve characteristics are also important in generating the pressure drop. We aimed to assess, in an ex vivo pulsatile mock loop, the hydrodynamic behavior of two bioprostheses, Trifecta and Mitroflow, to ascertain which geometric terms are limiting factors in hydrodynamic performance. At stroke volumes between 30 and 60 ml, Trifecta showed lower pressure drop, energy dissipation and valve resistance, and greater effective orifice area. This trend was overturned at higher stroke volumes, with Mitroflow slightly outperforming Trifecta. The geometric determinants were consistent with these results. Trifecta achieved its maximum opening area already at the lowest stroke volumes, featuring a divergent shape at the systolic peak. Mitroflow showed a complex opening pattern, featuring a convergent shape at the systolic peak for lower stroke volumes, while reaching its maximum opening area at higher stroke volumes, with a divergent shape. The two bioprostheses, although similar in design, displayed different biomechanical behaviors. The internal diameter of each bioprosthesis did not show to be strictly correlated with its hydrodynamic characteristics.

Hydrodynamic and Geometric Behavior of Two Pericardial Prostheses Implanted in Small Aortic Roots / G. Tasca, G. Beniamino Fiore, P. Redaelli, C. Romagnoni, A. Redaelli, A. Gamba, C. Antona, R. Vismara. - In: ASAIO JOURNAL. - ISSN 1058-2916. - 64:1(2018), pp. 86-90. [10.1097/MAT.0000000000000587]

Hydrodynamic and Geometric Behavior of Two Pericardial Prostheses Implanted in Small Aortic Roots

C. Romagnoni;C. Antona;
2018

Abstract

Hydrodynamic performance of stented bioprostheses is far below that of the native valve. One of the reasons is that the internal diameter of the prosthesis is usually smaller than that of the native valve. However, other valve characteristics are also important in generating the pressure drop. We aimed to assess, in an ex vivo pulsatile mock loop, the hydrodynamic behavior of two bioprostheses, Trifecta and Mitroflow, to ascertain which geometric terms are limiting factors in hydrodynamic performance. At stroke volumes between 30 and 60 ml, Trifecta showed lower pressure drop, energy dissipation and valve resistance, and greater effective orifice area. This trend was overturned at higher stroke volumes, with Mitroflow slightly outperforming Trifecta. The geometric determinants were consistent with these results. Trifecta achieved its maximum opening area already at the lowest stroke volumes, featuring a divergent shape at the systolic peak. Mitroflow showed a complex opening pattern, featuring a convergent shape at the systolic peak for lower stroke volumes, while reaching its maximum opening area at higher stroke volumes, with a divergent shape. The two bioprostheses, although similar in design, displayed different biomechanical behaviors. The internal diameter of each bioprosthesis did not show to be strictly correlated with its hydrodynamic characteristics.
Animals; Aortic Valve; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Hemodynamics; Hydrodynamics; Pericardium; Prosthesis Design; Stents; Stroke Volume; Swine
Settore MED/23 - Chirurgia Cardiaca
Settore ING-IND/34 - Bioingegneria Industriale
2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
Hydrodynamic_and_Geometric_Behavior_of_Two.13.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 277.15 kB
Formato Adobe PDF
277.15 kB Adobe PDF   Visualizza/Apri   Richiedi una copia