Breast lesions defined C3 at ultrasound (US)-guided fine needle aspiration cytology (FNAC) are probably benign, but exhibit atypias. We evaluate the results of US-guided vacuum assisted breast biopsy (VABB) of these lesions. Patients diagnosed C3 by US-FNAC, submitted to US-VABB and with a minimum follow-up of 36 months or surgery were enrolled. Cost outcome of this diagnostic protocol was evaluated. We evaluated 138 patients with non-palpable C3 lesions. In 2/138 (1.4%) cases VABB results were inadequate. VABB diagnosed: 17/138 (12.3%) malignant and 119/138 (86.2%) benign lesions. In 28/138 cases (20.3%) surgery retrieved 18/28 (64.3%) malignant lesions. One false negative result of VABB was observed. Sensitivity and specificity of VABB resulted 94.4% and 100%. Our diagnostic algorithm estimated a 45% mean decrease of costs using VABB when compared with surgical biopsy of all C3 lesions.

Ultrasound-guided vacuum assisted breast biopsy in the assessment of C3 breast lesions by ultrasound-guided fine needle aspiration cytology: results and costs in comparison with surgery / F. Abbate, L. Bacigalupo, A. Latronico, C. Trentin, S. Penco, S. Menna, G. Viale, E. Cassano, M. Bellomi. - In: THE BREAST. - ISSN 0960-9776. - 18:2(2009), pp. 73-77.

Ultrasound-guided vacuum assisted breast biopsy in the assessment of C3 breast lesions by ultrasound-guided fine needle aspiration cytology: results and costs in comparison with surgery

G. Viale;M. Bellomi
Ultimo
2009

Abstract

Breast lesions defined C3 at ultrasound (US)-guided fine needle aspiration cytology (FNAC) are probably benign, but exhibit atypias. We evaluate the results of US-guided vacuum assisted breast biopsy (VABB) of these lesions. Patients diagnosed C3 by US-FNAC, submitted to US-VABB and with a minimum follow-up of 36 months or surgery were enrolled. Cost outcome of this diagnostic protocol was evaluated. We evaluated 138 patients with non-palpable C3 lesions. In 2/138 (1.4%) cases VABB results were inadequate. VABB diagnosed: 17/138 (12.3%) malignant and 119/138 (86.2%) benign lesions. In 28/138 cases (20.3%) surgery retrieved 18/28 (64.3%) malignant lesions. One false negative result of VABB was observed. Sensitivity and specificity of VABB resulted 94.4% and 100%. Our diagnostic algorithm estimated a 45% mean decrease of costs using VABB when compared with surgical biopsy of all C3 lesions.
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore MED/08 - Anatomia Patologica
2009
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/66412
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact