The feasibility and reproducibility of a new ultrasonic method for the direct assessment of maximal varicose vein diameter (VVD) were evaluated. A study was also performed to demonstrate the capacity of the method to detect changes in venous diameter induced by a pharmacologic treatment. Patients with varicose vein disease were recruited. A method that allows the precise positioning of patient and transducer and performance of scans in a gel-bath was developed. Maximal VVD was recorded both in the standing and supine positions. The intraassay reproducibility was determined by replicate scans made within 15 minutes in both positions. The interobserver variability was assessed by comparing VVDs measured during the first phase baseline examination with those obtained during baseline examinations in the second phase of the study. The error in reproducibility of VVD determinations was 5.3% when diameters were evaluated in the standing position and 6.4% when assessed in the supine position. The intramethod agreement was high, with a bias between readings of 0.06 ±0.18 mm and of –0.02 ±0.19 mm, respectively, in standing and supine positions. Correlation coefficients were better than 0.99 in both positions. The method appears to be sensitive enough to detect small changes in VVDs induced by treatments. The proposed technique provides a tool of potential valid use in the detection and in vivo monitoring of VVD changes in patients with varicose vein disease. The method offers an innovative approach to obtain a quantitative assessment of varicose vein progression and of treatment effects, thus providing a basis for epidemiologic surveys

A new noninvasive method for the accurate and precise assessment of varicose vein diameters / D. Baldassarre, L. Pustina, S. Castelnuovo, A. Bondioli, M. Carlà, C.R. Sirtori. - In: ANGIOLOGY. - ISSN 0003-3197. - 54:5(2003), pp. 541-549. [10.1177/000331970305400503]

A new noninvasive method for the accurate and precise assessment of varicose vein diameters

D. Baldassarre;L. Pustina;S. Castelnuovo;C.R. Sirtori
2003

Abstract

The feasibility and reproducibility of a new ultrasonic method for the direct assessment of maximal varicose vein diameter (VVD) were evaluated. A study was also performed to demonstrate the capacity of the method to detect changes in venous diameter induced by a pharmacologic treatment. Patients with varicose vein disease were recruited. A method that allows the precise positioning of patient and transducer and performance of scans in a gel-bath was developed. Maximal VVD was recorded both in the standing and supine positions. The intraassay reproducibility was determined by replicate scans made within 15 minutes in both positions. The interobserver variability was assessed by comparing VVDs measured during the first phase baseline examination with those obtained during baseline examinations in the second phase of the study. The error in reproducibility of VVD determinations was 5.3% when diameters were evaluated in the standing position and 6.4% when assessed in the supine position. The intramethod agreement was high, with a bias between readings of 0.06 ±0.18 mm and of –0.02 ±0.19 mm, respectively, in standing and supine positions. Correlation coefficients were better than 0.99 in both positions. The method appears to be sensitive enough to detect small changes in VVDs induced by treatments. The proposed technique provides a tool of potential valid use in the detection and in vivo monitoring of VVD changes in patients with varicose vein disease. The method offers an innovative approach to obtain a quantitative assessment of varicose vein progression and of treatment effects, thus providing a basis for epidemiologic surveys
Cardiology and Cardiovascular Medicine
Settore BIO/14 - Farmacologia
2003
Article (author)
File in questo prodotto:
File Dimensione Formato  
BaldassarreEtAlli_NewNonInvasive_PrePrint.pdf

accesso aperto

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 524.65 kB
Formato Adobe PDF
524.65 kB Adobe PDF Visualizza/Apri
BaldassarreEtAlii_2003_VersioneEditoriale.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 147.39 kB
Formato Adobe PDF
147.39 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/66112
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact