Rationale and Objectives: To evaluate image quality, coronary interpretability and radiation exposure of coronary CT angiography (CCTA)performed in patients with atrial fibrillation (AF)with the latest scanner generation, comparing two different technical approaches. A new scanner that combines a 0.23 mm spatial resolution, a new generation of iterative reconstruction, fast gantry rotation time and the intracycle motion-correction algorithm to improve the temporal resolution was recently introduced in the clinical field. Materials and Methods: We enrolled 105 consecutive patients with chronic AF who performed CCTA with a whole-heart coverage high-definition CT scanner (16-cm z-axis coverage with 256 detector rows, 0.28 s gantry rotation time). Five of them were excluded for impaired renal function. Patients were randomized between a double acquisition protocol (50 patients, group 1)or a single acquisition protocol (50 patients, group 2). The image quality, coronary segment interpretability and effective dose (ED)of CCTA were assessed. Results: The mean HR during the scan was 85.6±21 bpm in group 1 vs. 83.7±23 bpm in Group 2, respectively (p < ns). In group 2, overall image quality was high and comparable with that of group 1 (Likert scale =3.2 ± 1.4 vs. 3.3 ± 1.2, p = ns, in group 1 and 2, respectively). Coronary interpretability was high and similar between the two groups (97.5% and 97.1% in group 1 and 2, p = ns, respectively). Mean ED was significantly higher in group 1 than in group 2 (5.3 ± 1.8 mSv vs. 2.7 ± 0.7 mSv, p < 0.001). Conclusion: The novel whole-heart coverage CT scanner allows to perform CCTA with a single-acquisition protocol with high image quality and low radiation exposure in AF patients.

Low-Dose Coronary CT Angiography in Patients with Atrial Fibrillation: Comparison of Image Quality and Radiation Exposure with Two Different Approaches / S. Mushtaq, G. Pontone, E. Conte, M. Guglielmo, E. Consiglio, M. Magatelli, M. Oliveira, G. Muscogiuri, A. Annoni, A. Baggiano, A. Formenti, M.E. Mancini, L. Di Odoardo, E. Melotti, C. Fiorentini, A.L. Bartorelli, M. Pepi, D. Andreini. - In: ACADEMIC RADIOLOGY. - ISSN 1076-6332. - 26:6(2019 Jun), pp. 791-797.

Low-Dose Coronary CT Angiography in Patients with Atrial Fibrillation: Comparison of Image Quality and Radiation Exposure with Two Different Approaches

G. Pontone
Secondo
;
E. Conte;M. Guglielmo;G. Muscogiuri;A. Baggiano;L. Di Odoardo;E. Melotti;A.L. Bartorelli;D. Andreini
Ultimo
2019

Abstract

Rationale and Objectives: To evaluate image quality, coronary interpretability and radiation exposure of coronary CT angiography (CCTA)performed in patients with atrial fibrillation (AF)with the latest scanner generation, comparing two different technical approaches. A new scanner that combines a 0.23 mm spatial resolution, a new generation of iterative reconstruction, fast gantry rotation time and the intracycle motion-correction algorithm to improve the temporal resolution was recently introduced in the clinical field. Materials and Methods: We enrolled 105 consecutive patients with chronic AF who performed CCTA with a whole-heart coverage high-definition CT scanner (16-cm z-axis coverage with 256 detector rows, 0.28 s gantry rotation time). Five of them were excluded for impaired renal function. Patients were randomized between a double acquisition protocol (50 patients, group 1)or a single acquisition protocol (50 patients, group 2). The image quality, coronary segment interpretability and effective dose (ED)of CCTA were assessed. Results: The mean HR during the scan was 85.6±21 bpm in group 1 vs. 83.7±23 bpm in Group 2, respectively (p < ns). In group 2, overall image quality was high and comparable with that of group 1 (Likert scale =3.2 ± 1.4 vs. 3.3 ± 1.2, p = ns, in group 1 and 2, respectively). Coronary interpretability was high and similar between the two groups (97.5% and 97.1% in group 1 and 2, p = ns, respectively). Mean ED was significantly higher in group 1 than in group 2 (5.3 ± 1.8 mSv vs. 2.7 ± 0.7 mSv, p < 0.001). Conclusion: The novel whole-heart coverage CT scanner allows to perform CCTA with a single-acquisition protocol with high image quality and low radiation exposure in AF patients.
English
Atrial fibrillation; Coronary CT angiography; Radiation exposure
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
giu-2019
Elsevier
26
6
791
797
7
Pubblicato
Periodico con rilevanza internazionale
Aderisco
info:eu-repo/semantics/article
Low-Dose Coronary CT Angiography in Patients with Atrial Fibrillation: Comparison of Image Quality and Radiation Exposure with Two Different Approaches / S. Mushtaq, G. Pontone, E. Conte, M. Guglielmo, E. Consiglio, M. Magatelli, M. Oliveira, G. Muscogiuri, A. Annoni, A. Baggiano, A. Formenti, M.E. Mancini, L. Di Odoardo, E. Melotti, C. Fiorentini, A.L. Bartorelli, M. Pepi, D. Andreini. - In: ACADEMIC RADIOLOGY. - ISSN 1076-6332. - 26:6(2019 Jun), pp. 791-797.
reserved
Prodotti della ricerca::01 - Articolo su periodico
18
262
Article (author)
si
S. Mushtaq, G. Pontone, E. Conte, M. Guglielmo, E. Consiglio, M. Magatelli, M. Oliveira, G. Muscogiuri, A. Annoni, A. Baggiano, A. Formenti, M.E. Mancini, L. Di Odoardo, E. Melotti, C. Fiorentini, A.L. Bartorelli, M. Pepi, D. Andreini
File in questo prodotto:
File Dimensione Formato  
Low Dose.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 787.26 kB
Formato Adobe PDF
787.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/658327
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact