Purpose: The purpose of this study was to compare the prostate contours drawn by two radiation oncologists and one radiologist on magnetic resonance (MR) and transrectal ultrasound (TRUS) images. TRUS intra- and inter-fraction variability as well as TRUS vs. MR inter-modality and inter-operator variability were studied. Material and methods: Thirty patients affected by localized prostate cancer and treated with interstitial high-dose-rate (HDR) prostate brachytherapy at the National Cancer Institute in Milan were included in this study. Twenty-five patients received an exclusive two-fraction (14 Gy/fraction) treatment, while the other 5 received a single 14 Gy fraction as a boost after external beam radiotherapy. The prostate was contoured on TRUS images acquired before (virtual US) and after (real US) needle implant by two radiation oncologists, whereas on MR prostate was independently contoured by the same radiation oncologists (MR1, MR2) and by a dedicated radiologist (MR3). Absolute differences of prostate volumes (∆V) and craniocaudal extents (∆dz) were evaluated. The Dice's coefficient (DC) was calculated to quantify spatial overlap between MR contours. Results: Significant difference was found between Vvirtual and Vlive (p < 0.001) for the first treatment fractions and between VMR1 and VMR2 (p = 0.043). Significant difference between cranio-caudal extents was found between dzvirtual and dzlive (p < 0.033) for the first treatment fractions, between dzvirtual of the first treatment fractions and dzMR1 (p < 0.001) and between dzMR1 and dzMR3 (p < 0.01). Oedema might be responsible for some of the changes in US volumes. Average DC values resulting from the comparison MR1 vs. MR2, MR1 vs. MR3 and MR2 vs. MR3 were 0.95 ± 0.04 (range, 0.82-0.99), 0.87 ± 0.04 (range, 0.73-0.91) and 0.87 ± 0.04 (range, 0.72-0.91), respectively. Conclusions: Our results demonstrate the importance of a multiprofessional approach to TRUS-guided HDR prostate brachytherapy. Specific training in MR and US prostate imaging is recommended for centers that are unfamiliar with HDR prostate brachytherapy.

Pre-implant magnetic resonance and transrectal ultrasound imaging in high-dose-rate prostate brachytherapy : comparison of prostate volumes, craniocaudal extents, and contours / S. Grisotto, A. Cerrotta, B. Pappalardi, M. Carrara, A. Messina, C. Tenconi, R. Valdagni, C. Fallai. - In: JOURNAL OF CONTEMPORARY BRACHYTHERAPY. - ISSN 1689-832X. - 10:4(2018 Aug), pp. 285-290. [10.5114/jcb.2018.77947]

Pre-implant magnetic resonance and transrectal ultrasound imaging in high-dose-rate prostate brachytherapy : comparison of prostate volumes, craniocaudal extents, and contours

S. Grisotto;C. Tenconi;R. Valdagni;
2018

Abstract

Purpose: The purpose of this study was to compare the prostate contours drawn by two radiation oncologists and one radiologist on magnetic resonance (MR) and transrectal ultrasound (TRUS) images. TRUS intra- and inter-fraction variability as well as TRUS vs. MR inter-modality and inter-operator variability were studied. Material and methods: Thirty patients affected by localized prostate cancer and treated with interstitial high-dose-rate (HDR) prostate brachytherapy at the National Cancer Institute in Milan were included in this study. Twenty-five patients received an exclusive two-fraction (14 Gy/fraction) treatment, while the other 5 received a single 14 Gy fraction as a boost after external beam radiotherapy. The prostate was contoured on TRUS images acquired before (virtual US) and after (real US) needle implant by two radiation oncologists, whereas on MR prostate was independently contoured by the same radiation oncologists (MR1, MR2) and by a dedicated radiologist (MR3). Absolute differences of prostate volumes (∆V) and craniocaudal extents (∆dz) were evaluated. The Dice's coefficient (DC) was calculated to quantify spatial overlap between MR contours. Results: Significant difference was found between Vvirtual and Vlive (p < 0.001) for the first treatment fractions and between VMR1 and VMR2 (p = 0.043). Significant difference between cranio-caudal extents was found between dzvirtual and dzlive (p < 0.033) for the first treatment fractions, between dzvirtual of the first treatment fractions and dzMR1 (p < 0.001) and between dzMR1 and dzMR3 (p < 0.01). Oedema might be responsible for some of the changes in US volumes. Average DC values resulting from the comparison MR1 vs. MR2, MR1 vs. MR3 and MR2 vs. MR3 were 0.95 ± 0.04 (range, 0.82-0.99), 0.87 ± 0.04 (range, 0.73-0.91) and 0.87 ± 0.04 (range, 0.72-0.91), respectively. Conclusions: Our results demonstrate the importance of a multiprofessional approach to TRUS-guided HDR prostate brachytherapy. Specific training in MR and US prostate imaging is recommended for centers that are unfamiliar with HDR prostate brachytherapy.
HDR prostate brachytherapy; MR imaging; TRUS-guided real-time treatment planning
Settore MED/36 - Diagnostica per Immagini e Radioterapia
ago-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
JCB-10-33584.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 642.27 kB
Formato Adobe PDF
642.27 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/657746
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact