The purposes of the study were to evaluate the bond strength of bioceramic TotalFill root repair material (RRM) in retrograde cavities prepared using Er:YAG and Er,Cr:YSGG laser and steel bur, and to analyze failure modes. The root canals of 30 single-rooted teeth were endodontically treated, their root-ends were resected using a diamond bur, and the teeth were randomly divided into three groups (N = 10) according to the retrograde cavity preparation technique: (1) Er:YAG laser, (2) Er,Cr:YSGG laser, and (3) steel bur. All retrograde cavities were filled with the TotalFill RRM which was prepared according to the manufacturers’ instructions. Push-out test was performed using universal testing machine, and failure mode was analyzed using a scanning electron microscope. The data were analyzed using one-way ANOVA, post hoc analysis with Bonferroni correction, and Fisher-Freeman-Halton exact test (p < 0.05). In the Er:YAG-, Er,Cr:YSGG-, and steel bur–prepared cavities, mean bond strengths (MPa) were 12.76, 8.44, and 6.01, respectively. The bond strength of the TotalFill RRM to dentin was significantly higher in the Er:YAG laser compared with the steel bur–prepared cavities (p = 0.004). The bond strength was not significantly different between the Er:YAG and Er,Cr:YSGG cavities (p = 0.074) and between the Er,Cr:YSGG and bur cavities (p = 0.648). In the cavities prepared by the Er,Cr:YSGG laser and bur, the failure mode of the TotalFill RRM was predominantly mixed, then adhesive and cohesive. In the Er:YAG laser–prepared cavities, the most common failure mode was adhesive, followed by mixed type and no cohesive failure. The bond strength of the TotalFill RRM to dentin was highest in the group of retrograde cavities prepared by the Er:YAG laser.
Influence of different laser-assisted retrograde cavity preparation techniques on bond strength of bioceramic-based material to root dentine / S. Kadić, A. Baraba, I. Miletić, A.C. Ionescu, E. Brambilla, A. Ivanišević Malčić, D. Gabrić. - In: LASERS IN MEDICAL SCIENCE. - ISSN 0268-8921. - (2019 Jul 04). [Epub ahead of print] [10.1007/s10103-019-02835-z]
Influence of different laser-assisted retrograde cavity preparation techniques on bond strength of bioceramic-based material to root dentine
A.C. IonescuInvestigation
;E. BrambillaSupervision
;
2019
Abstract
The purposes of the study were to evaluate the bond strength of bioceramic TotalFill root repair material (RRM) in retrograde cavities prepared using Er:YAG and Er,Cr:YSGG laser and steel bur, and to analyze failure modes. The root canals of 30 single-rooted teeth were endodontically treated, their root-ends were resected using a diamond bur, and the teeth were randomly divided into three groups (N = 10) according to the retrograde cavity preparation technique: (1) Er:YAG laser, (2) Er,Cr:YSGG laser, and (3) steel bur. All retrograde cavities were filled with the TotalFill RRM which was prepared according to the manufacturers’ instructions. Push-out test was performed using universal testing machine, and failure mode was analyzed using a scanning electron microscope. The data were analyzed using one-way ANOVA, post hoc analysis with Bonferroni correction, and Fisher-Freeman-Halton exact test (p < 0.05). In the Er:YAG-, Er,Cr:YSGG-, and steel bur–prepared cavities, mean bond strengths (MPa) were 12.76, 8.44, and 6.01, respectively. The bond strength of the TotalFill RRM to dentin was significantly higher in the Er:YAG laser compared with the steel bur–prepared cavities (p = 0.004). The bond strength was not significantly different between the Er:YAG and Er,Cr:YSGG cavities (p = 0.074) and between the Er,Cr:YSGG and bur cavities (p = 0.648). In the cavities prepared by the Er,Cr:YSGG laser and bur, the failure mode of the TotalFill RRM was predominantly mixed, then adhesive and cohesive. In the Er:YAG laser–prepared cavities, the most common failure mode was adhesive, followed by mixed type and no cohesive failure. The bond strength of the TotalFill RRM to dentin was highest in the group of retrograde cavities prepared by the Er:YAG laser.File | Dimensione | Formato | |
---|---|---|---|
2019 Laser Croazia 10.1007@s10103-019-02835-z.pdf
accesso riservato
Descrizione: Influence of different laser-assisted retrograde cavity preparation techniques on bond strength of bioceramic-based material to root dentine
Tipologia:
Publisher's version/PDF
Dimensione
790.23 kB
Formato
Adobe PDF
|
790.23 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.