Background: Blood loss for laboratory testing may contribute to hospital-acquired anemia. When implementing the core laboratory (core-lab) section, we consolidated first-line tests decreasing the number of tubes previously dispatched to different sites. Here, hypothesized benefits of the amount of blood volume drawn were explored. Methods: We retrieved, using a laboratory information system (LIS), the number of tubes received by laboratories interested in the change from all clinical wards in a year-based period, i.e. 2013 for pre-core-lab and 2015 for core-lab system, respectively. Data were expressed as the overall number of tubes sent to laboratories, the corresponding blood volume, and the number of laboratory tests performed, normalized for the number of inpatients. Results: After consolidation, the average number of blood tubes per inpatient significantly decreased (12.6 vs. 10.7, p < 0.001). However, intensive care units (ICUs) did not reduce the number of tubes per patient, according to the needs of daily monitoring of their clinical status. The average blood volume sent to laboratories did not vary significantly because serum tubes for core-lab required higher volumes for testing up to 55 analytes in the same transaction. Finally, the number of requested tests per patient during the new osystem slightly decreased (−2.6%). Conclusions: Total laboratory automation does not automatically mean reducing iatrogenic blood loss. The new system affected the procedure of blood drawing in clinical wards by significantly reducing the number of handled tubes, producing a benefit in terms of costs, labor and time consumption. Except in ICUs, this also slightly promoted some blood saving. ICUs which engage in phlebotomizing patients daily, did not take advantage from the test consolidation.

Impact of total automation consolidating first-line laboratory tests on diagnostic blood loss / S. Pasqualetti, E. Aloisio, S. Birindelli, A. Dolci, M. Panteghini. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - (2019 May 30). [Epub ahead of print] [10.1515/cclm-2019-0133]

Impact of total automation consolidating first-line laboratory tests on diagnostic blood loss

E. Aloisio;A. Dolci;M. Panteghini
2019

Abstract

Background: Blood loss for laboratory testing may contribute to hospital-acquired anemia. When implementing the core laboratory (core-lab) section, we consolidated first-line tests decreasing the number of tubes previously dispatched to different sites. Here, hypothesized benefits of the amount of blood volume drawn were explored. Methods: We retrieved, using a laboratory information system (LIS), the number of tubes received by laboratories interested in the change from all clinical wards in a year-based period, i.e. 2013 for pre-core-lab and 2015 for core-lab system, respectively. Data were expressed as the overall number of tubes sent to laboratories, the corresponding blood volume, and the number of laboratory tests performed, normalized for the number of inpatients. Results: After consolidation, the average number of blood tubes per inpatient significantly decreased (12.6 vs. 10.7, p < 0.001). However, intensive care units (ICUs) did not reduce the number of tubes per patient, according to the needs of daily monitoring of their clinical status. The average blood volume sent to laboratories did not vary significantly because serum tubes for core-lab required higher volumes for testing up to 55 analytes in the same transaction. Finally, the number of requested tests per patient during the new osystem slightly decreased (−2.6%). Conclusions: Total laboratory automation does not automatically mean reducing iatrogenic blood loss. The new system affected the procedure of blood drawing in clinical wards by significantly reducing the number of handled tubes, producing a benefit in terms of costs, labor and time consumption. Except in ICUs, this also slightly promoted some blood saving. ICUs which engage in phlebotomizing patients daily, did not take advantage from the test consolidation.
diagnostic blood loss; hospital-acquired anemia; total laboratory automation
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
30-mag-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
[(CCLM)] Impact of total automation consolidating first-line laboratory tests on diagnostic blood loss.pdf

Open Access dal 31/05/2020

Tipologia: Publisher's version/PDF
Dimensione 128.37 kB
Formato Adobe PDF
128.37 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/653319
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
social impact