Gel dosimetry has proved to be a valuable technique for absorbed dose distribution measurements in radiotherapy. FriXy-gel dosimeters consist of Fricke (ferrous sulphate) solution infused with xylenol orange. The solution is incorporated to a gel matrix in order to fix it to a solid structure allowing good spatial resolution and is imaged with a transportable optical system, measuring visible light transmittance before and after irradiation. This paper presents an evaluation of total photon mass attenuation coefficients at energies in the range of 50 keV-10MeV for the radiochromic FriXy gel dosimeter sensitive material. Mass attenuation coefficient estimations have been performed by means of Monte Carlo (PENELOPE) simulations. These calculations have been carried out for the FriXy gel sensitive material as well as for soft tissue (ICRU) and pure liquid water; a comparison of the obtained data shows good agreement between the different materials.

Fricke Gel dosimeter tissue-equivalence : a Monte Carlo study / M. Valente, G. Bartesaghi, G. Gambarini, D. Brusa, G. Castellano, M. Carrara - In: Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications. Proceedings of the 10th Conference / [a cura di] M. Barone, A. Gaddi, C. Leroy, L. Price, P. G. Rancoita, R. Ruchti. - Singapore : World Scientific Publishing, 2007. - ISBN 978-981-281-908-6. - pp. 605-609 (( Intervento presentato al 10. convegno International Conference on Astroparticle, Particle and Space Physics, Detectors and Medical Applications tenutosi a Como nel 2007.

Fricke Gel dosimeter tissue-equivalence : a Monte Carlo study

M. Valente
Primo
;
G. Bartesaghi
Secondo
;
G. Gambarini;M. Carrara
Ultimo
2007

Abstract

Gel dosimetry has proved to be a valuable technique for absorbed dose distribution measurements in radiotherapy. FriXy-gel dosimeters consist of Fricke (ferrous sulphate) solution infused with xylenol orange. The solution is incorporated to a gel matrix in order to fix it to a solid structure allowing good spatial resolution and is imaged with a transportable optical system, measuring visible light transmittance before and after irradiation. This paper presents an evaluation of total photon mass attenuation coefficients at energies in the range of 50 keV-10MeV for the radiochromic FriXy gel dosimeter sensitive material. Mass attenuation coefficient estimations have been performed by means of Monte Carlo (PENELOPE) simulations. These calculations have been carried out for the FriXy gel sensitive material as well as for soft tissue (ICRU) and pure liquid water; a comparison of the obtained data shows good agreement between the different materials.
Settore FIS/01 - Fisica Sperimentale
2007
Book Part (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/64464
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact