Cardiac output is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, cardiac output determination during exercise had been only possible through invasive methods, which were not practical in the clinical setting. Because V O2 is cardiac output times arteriovenous content difference, evaluation of cardiac output is usually included in its measurement. Because of the difficulty of directly measuring peak exercise cardiac output, indirect surrogate parameters have been proposed, but with only modest clinical usefulness. Direct measurement of cardiac output can now be made by several noninvasive techniques, such as rebreathing inert gases, impedance cardiology, thoracic bioreactance, estimated continuous cardiac output technology, and transthoracic echocardiography coupled to cardiopulmonary exercise testing, which allow more definitive results and better understanding of the underlying physiopathology.

Measuring cardiac output during cardiopulmonary exercise testing / C. Vignati, G. Cattadori. - In: ANNALS OF THE AMERICAN THORACIC SOCIETY. - ISSN 2325-6621. - 14:suppl. 1(2017), pp. S48-S52. [10.1513/AnnalsATS.201611-852FR]

Measuring cardiac output during cardiopulmonary exercise testing

C. Vignati
;
G. Cattadori
2017

Abstract

Cardiac output is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, cardiac output determination during exercise had been only possible through invasive methods, which were not practical in the clinical setting. Because V O2 is cardiac output times arteriovenous content difference, evaluation of cardiac output is usually included in its measurement. Because of the difficulty of directly measuring peak exercise cardiac output, indirect surrogate parameters have been proposed, but with only modest clinical usefulness. Direct measurement of cardiac output can now be made by several noninvasive techniques, such as rebreathing inert gases, impedance cardiology, thoracic bioreactance, estimated continuous cardiac output technology, and transthoracic echocardiography coupled to cardiopulmonary exercise testing, which allow more definitive results and better understanding of the underlying physiopathology.
No
English
cardiac output; cardiopulmonary exercise testing; heart disease
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
2017
American Thoracic Society
14
suppl. 1
S48
S52
5
Pubblicato
Periodico con rilevanza internazionale
scopus
pubmed
crossref
Aderisco
info:eu-repo/semantics/article
Measuring cardiac output during cardiopulmonary exercise testing / C. Vignati, G. Cattadori. - In: ANNALS OF THE AMERICAN THORACIC SOCIETY. - ISSN 2325-6621. - 14:suppl. 1(2017), pp. S48-S52. [10.1513/AnnalsATS.201611-852FR]
reserved
Prodotti della ricerca::01 - Articolo su periodico
2
262
Article (author)
no
C. Vignati, G. Cattadori
File in questo prodotto:
File Dimensione Formato  
annalsats.201611-852fr.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 607.79 kB
Formato Adobe PDF
607.79 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/633032
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact