Pericardiocentesis is useful in the diagnosis and treatment of pericardial effusive disease. To date, a number of methods have been developed to reduce complications and increase the success rate of the procedure. The aim of the present study was to evaluate the efficacy and the safety of echocardiography-guided pericardiocentesis under continuous echocardiographic monitoring in the management of pericardial effusion. We prospectively performed 161 pericardiocentesis procedures in 141 patients admitted from 1993 to 2015 in 3 centers. This procedure was performed for tamponade or large pericardial effusion in 157 cases and for diagnosis in 4 cases. A percutaneous puncture was performed where the largest amount of fluid was detected. To perform a real-time echo-guided procedure, a multi-angle bracket was mounted on the echocardiographic probe to support the needle and enable its continuous visualization during the puncture. The procedure was successful in 160 of 161 cases (99%). Two major complications occurred (1.2%): 1 mediastinal hematoma that required surgical drainage in a patient on anticoagulant therapy and 1 pleuropericardial shunt requiring thoracentesis. Seven minor complications occurred (4.3%): 1 pleuropericardial shunt, 1 case of transient AV type III block, 3 vasovagal reactions (1 with syncope), and 2 cases of acute pulmonary edema managed with medical therapy. No punctures of any cardiac chamber occurred, and emergency surgical drainage was not required in any case. In conclusion, echocardiography-guided pericardiocentesis under continuous visualization is effective, safe, and easy to perform, even in hospitals with low volumes of procedures with or without cardiac surgery.

Safety, Efficacy, and Complications of Pericardiocentesis by Real-Time Echo-Monitored Procedure / S. Maggiolini, G. Gentile, A. Farina, C.C. De Carlini, L. Lenatti, E. Meles, F. Achilli, A. Tempesta, A. Brucato, M. Imazio. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - 117:8(2016), pp. 1369-1374. [10.1016/j.amjcard.2016.01.043]

Safety, Efficacy, and Complications of Pericardiocentesis by Real-Time Echo-Monitored Procedure

A. Brucato;
2016

Abstract

Pericardiocentesis is useful in the diagnosis and treatment of pericardial effusive disease. To date, a number of methods have been developed to reduce complications and increase the success rate of the procedure. The aim of the present study was to evaluate the efficacy and the safety of echocardiography-guided pericardiocentesis under continuous echocardiographic monitoring in the management of pericardial effusion. We prospectively performed 161 pericardiocentesis procedures in 141 patients admitted from 1993 to 2015 in 3 centers. This procedure was performed for tamponade or large pericardial effusion in 157 cases and for diagnosis in 4 cases. A percutaneous puncture was performed where the largest amount of fluid was detected. To perform a real-time echo-guided procedure, a multi-angle bracket was mounted on the echocardiographic probe to support the needle and enable its continuous visualization during the puncture. The procedure was successful in 160 of 161 cases (99%). Two major complications occurred (1.2%): 1 mediastinal hematoma that required surgical drainage in a patient on anticoagulant therapy and 1 pleuropericardial shunt requiring thoracentesis. Seven minor complications occurred (4.3%): 1 pleuropericardial shunt, 1 case of transient AV type III block, 3 vasovagal reactions (1 with syncope), and 2 cases of acute pulmonary edema managed with medical therapy. No punctures of any cardiac chamber occurred, and emergency surgical drainage was not required in any case. In conclusion, echocardiography-guided pericardiocentesis under continuous visualization is effective, safe, and easy to perform, even in hospitals with low volumes of procedures with or without cardiac surgery.
Settore MED/09 - Medicina Interna
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0002914916301655-main Safety.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 859.13 kB
Formato Adobe PDF
859.13 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/630120
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 58
social impact