Intrahepatic total HBV DNA (it-HBV DNA) level might reflect the size of virus reservoir and correlate with the histological status of the liver. To quantitate it-HBV DNA in a series of 70 liver biopsies obtained from hepatitis B chronic patients, a modified version of the COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0 was used for this purpose. The linearity and reproducibility of the modified protocol was tested by quantifying serial dilutions of a full-length HBV containing plasmid and it-HBV DNA from a reference patient. A good linear trend between the expected values and those generated by the assay was observed at different concentrations of both plasmid and reference patient (R 2 = 0.994 and 0.962, respectively). Differences between the values obtained in two independent runs were ≤0.3 log IU for the plasmid and ≤0.6 log IU/mg for the reference patient, showing a high inter-run reproducibility. In the 70 liver biopsies, it-HBV DNA level ranged from 1.4 to 5.4 log IU/mg, with a good linearity and reproducibility between the values obtained in two runs [R 2 = 0.981; median (IQR) difference of it-HBV DNA 0.05 (0.02-0.09) IU/mg]. The modified COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0 allows an accurate quantitation of it-HBV DNA. Its determination may have prognostic value and may be a useful tool for the new therapeutic strategies aimed at eradicating the HBV infection.
Quantification of intrahepatic total HBV DNA in liver biopsies of HBV‑infected patients by a modified version of COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0 / R. Salpini, L. Piermatteo, U. Gill, A. Battisti, F. Stazi, T. Guenci, S. Giannella, V. Serafini, P.T.F. Kennedy, C.F. Perno, V. Svicher, M. Ciotti. - In: MEDICAL MICROBIOLOGY AND IMMUNOLOGY. - ISSN 0300-8584. - 206:4(2017 Aug), pp. 295-299. [10.1007/s00430-017-0504-3]
Quantification of intrahepatic total HBV DNA in liver biopsies of HBV‑infected patients by a modified version of COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0
C.F. Perno;
2017
Abstract
Intrahepatic total HBV DNA (it-HBV DNA) level might reflect the size of virus reservoir and correlate with the histological status of the liver. To quantitate it-HBV DNA in a series of 70 liver biopsies obtained from hepatitis B chronic patients, a modified version of the COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0 was used for this purpose. The linearity and reproducibility of the modified protocol was tested by quantifying serial dilutions of a full-length HBV containing plasmid and it-HBV DNA from a reference patient. A good linear trend between the expected values and those generated by the assay was observed at different concentrations of both plasmid and reference patient (R 2 = 0.994 and 0.962, respectively). Differences between the values obtained in two independent runs were ≤0.3 log IU for the plasmid and ≤0.6 log IU/mg for the reference patient, showing a high inter-run reproducibility. In the 70 liver biopsies, it-HBV DNA level ranged from 1.4 to 5.4 log IU/mg, with a good linearity and reproducibility between the values obtained in two runs [R 2 = 0.981; median (IQR) difference of it-HBV DNA 0.05 (0.02-0.09) IU/mg]. The modified COBAS®Ampliprep/COBAS®TaqMan HBV test v2.0 allows an accurate quantitation of it-HBV DNA. Its determination may have prognostic value and may be a useful tool for the new therapeutic strategies aimed at eradicating the HBV infection.File | Dimensione | Formato | |
---|---|---|---|
10.1007_s00430-017-0504-3.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
572.98 kB
Formato
Adobe PDF
|
572.98 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.