Patients resuscitated from cardiac arrest develop a pathophysiological state named "post-cardiac arrest syndrome." Post-resuscitation myocardial dysfunction is a common feature of this syndrome, and many patients eventually die from cardiovascular failure. Cardiogenic shock accounts for most deaths in the first 3 days, when post-resuscitation myocardial dysfunction peaks. Thus, identification and treatment of cardiovascular failure is one of the key therapeutic goals during hospitalization of post-cardiac arrest patients. Patients with hemodynamic instability may require advanced cardiac output monitoring. Inotropes and vasopressors should be considered if hemodynamic goals are not achieved despite optimized preload. If these measures fail to restore adequate organ perfusion, a mechanical circulatory assistance device may be considered. Adequate organ perfusion should be ensured in the absence of definitive data on the optimal target pressure goals. Hemodynamic goals should also take into account targeted temperature management and its effect on the cardiovascular function.
The optimal hemodynamics management of post-cardiac arrest shock / T. Pellis, F. Sanfilippo, G. Ristagno. - In: BAILLIERE'S BEST PRACTICE IN CLINICAL ANAESTHESIOLOGY. - ISSN 1521-6896. - 29:4(2015 Dec), pp. 485-495. [10.1016/j.bpa.2015.10.002]
The optimal hemodynamics management of post-cardiac arrest shock
G. Ristagno
2015
Abstract
Patients resuscitated from cardiac arrest develop a pathophysiological state named "post-cardiac arrest syndrome." Post-resuscitation myocardial dysfunction is a common feature of this syndrome, and many patients eventually die from cardiovascular failure. Cardiogenic shock accounts for most deaths in the first 3 days, when post-resuscitation myocardial dysfunction peaks. Thus, identification and treatment of cardiovascular failure is one of the key therapeutic goals during hospitalization of post-cardiac arrest patients. Patients with hemodynamic instability may require advanced cardiac output monitoring. Inotropes and vasopressors should be considered if hemodynamic goals are not achieved despite optimized preload. If these measures fail to restore adequate organ perfusion, a mechanical circulatory assistance device may be considered. Adequate organ perfusion should be ensured in the absence of definitive data on the optimal target pressure goals. Hemodynamic goals should also take into account targeted temperature management and its effect on the cardiovascular function.File | Dimensione | Formato | |
---|---|---|---|
BestPracticeResClinAnesth_Hemodynamics.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
222.47 kB
Formato
Adobe PDF
|
222.47 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.