After installation of Mo liners in the source NIO1 (Negative Ion Optimization phase 1), hydrogen plasmas in a continuous regime operation (much longer than one hour) are routinely maintained, with more than 1 kW rf power and 0.5 Pa pressure, allowing a systematic investigation of pure H- volume effect, which requests a much lower acceleration voltage Vs ≅ 12 kV than future Cs operations at Vs ≅ 60 kV. A new extraction grid EG was installed (replacing some eroded insulators) and preliminary beam images are compared to old EG ones, discussing effects of different deflection field strength and need of intermediate values. Large improvements in beam diagnostics and the effect of installation of a cryogenic pump are also reported.

Extraction of many H- beamlets from ion source NIO1 / M. Cavenago, G. Serianni, P. Veltri, M. De Muri, M. Agostini, V. Antoni, C. Baltador, P. Barbato, M. Barbisan, A. Barzon, L. Baseggio, M. Bigi, M. Brombin, L. Buonincontri, V. Cervaro, F.D. Agostini, E. Fagotti, L. Franchin, N. Ippolito, T. Kulevoy, B. Laterza, L. Lotto, A. Ludovici, G. Maero, M. Maniero, L. Migliorato, A. Minarello, P. Minelli, F. Molon, G. Moro, R. Pasqualotto, P. Jain, T. Patton, S. Petrenko, A. Pimazzoni, D. Ravarotto, M. Recchia, L. Romanato, M. Romé, F. Rossetto, E. Sartori, M. Sattin, F. Spinazzè, F. Stivanello, F. Taccogna, M. Tollin, L. Trevisan, M. Ugoletti, V. Variale, M. Zanini, B. Zaniol, S. Zucchetti, P. Sonato (AIP CONFERENCE PROCEEDINGS). - In: Proceedings of the 17th International Conference on Ion Sources[s.l] : American Institute of Physics Inc., 2018. - ISBN 9780735417274. - pp. 1-3 (( Intervento presentato al 17. convegno International Conference on Ion Sources tenutosi a Geneva nel 2017.

Extraction of many H- beamlets from ion source NIO1

G. Maero;M. Romé;
2018

Abstract

After installation of Mo liners in the source NIO1 (Negative Ion Optimization phase 1), hydrogen plasmas in a continuous regime operation (much longer than one hour) are routinely maintained, with more than 1 kW rf power and 0.5 Pa pressure, allowing a systematic investigation of pure H- volume effect, which requests a much lower acceleration voltage Vs ≅ 12 kV than future Cs operations at Vs ≅ 60 kV. A new extraction grid EG was installed (replacing some eroded insulators) and preliminary beam images are compared to old EG ones, discussing effects of different deflection field strength and need of intermediate values. Large improvements in beam diagnostics and the effect of installation of a cryogenic pump are also reported.
Physics and Astronomy (all)
Settore FIS/01 - Fisica Sperimentale
Settore FIS/03 - Fisica della Materia
2018
Bergoz Instrumentation
D-Pace
et al.
FRIATEC
Oregon Physics
Pantechnik
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
AIPProc2018.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.39 MB
Formato Adobe PDF
1.39 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/616026
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact