INTRODUCTION: Trabecular bone score (TBS) is an indirect index of trabecular microarchitecture derived from lumbar spine dual-energy X-ray absorptiometry. Previous phantom study showed that an increase in soft tissue thickness does not affect TBS reproducibility. We investigated the effect of increasing body mass index (BMI) and waist circumference on TBS precision error on patients, compared to bone mineral density (BMD). METHODOLOGY: A population of postmenopausal Caucasian women was distributed in 3 different BMI (normal, overweight, and class I obesity), plus 2 further groups based on waist circumference diameter (≤88 cm and >88 cm, respectively). In vivo precision error was calculated on 30 consecutive subjects that were scanned 2 times, with patient repositioning, using the Hologic QDR-Discovery W densitometer. Coefficient of variation, percent least significant change, and reproducibility were calculated according to the International Society for Clinical Densitometry guidelines. RESULTS: Ninety-five women aged 66 ± 10 (mean ± standard deviation) were included. No significant differences were found both for BMD and TBS precision errors, respectively, when comparing BMI groups and waist circumference groups. BMD reproducibility ranged from 95.9% (BMI > 30 kg/m2) to 97.5% (BMI < 25 kg/m2). TBS reproducibility ranged between 95.8% (BMI = 25-29.9 kg/m2, waist circumference > 88 cm) and 96.6% (BMI < 25 kg/m2). With the exception of obese group, a significant difference was found between BMD and TBS reproducibility, being that of TBS slightly lower than BMD. A significant decrease of TBS values was found between normal and obese subjects, as well as between waist circumference groups. CONCLUSIONS: TBS precision error is not affected by BMI and waist circumference differences. TBS reproducibility showed to be slightly lower than that of BMD, but this difference was mitigated in obese patients. A negative association was found between the amount of fat mass and TBS mean values.

Fat Mass Does Not Increase the Precision Error of Trabecular Bone Score Measurements / C. Messina, C. Buonomenna, G. Menon, S. Magnani, D. Albano, S. Gitto, F.M. Ulivieri, L.M. Sconfienza. - In: JOURNAL OF CLINICAL DENSITOMETRY. - ISSN 1094-6950. - 22:3(2019), pp. 359-366. [10.1016/j.jocd.2019.01.001]

Fat Mass Does Not Increase the Precision Error of Trabecular Bone Score Measurements

C. Messina
Primo
;
C. Buonomenna
Secondo
;
S. Magnani;D. Albano;S. Gitto;L.M. Sconfienza
Ultimo
2019

Abstract

INTRODUCTION: Trabecular bone score (TBS) is an indirect index of trabecular microarchitecture derived from lumbar spine dual-energy X-ray absorptiometry. Previous phantom study showed that an increase in soft tissue thickness does not affect TBS reproducibility. We investigated the effect of increasing body mass index (BMI) and waist circumference on TBS precision error on patients, compared to bone mineral density (BMD). METHODOLOGY: A population of postmenopausal Caucasian women was distributed in 3 different BMI (normal, overweight, and class I obesity), plus 2 further groups based on waist circumference diameter (≤88 cm and >88 cm, respectively). In vivo precision error was calculated on 30 consecutive subjects that were scanned 2 times, with patient repositioning, using the Hologic QDR-Discovery W densitometer. Coefficient of variation, percent least significant change, and reproducibility were calculated according to the International Society for Clinical Densitometry guidelines. RESULTS: Ninety-five women aged 66 ± 10 (mean ± standard deviation) were included. No significant differences were found both for BMD and TBS precision errors, respectively, when comparing BMI groups and waist circumference groups. BMD reproducibility ranged from 95.9% (BMI > 30 kg/m2) to 97.5% (BMI < 25 kg/m2). TBS reproducibility ranged between 95.8% (BMI = 25-29.9 kg/m2, waist circumference > 88 cm) and 96.6% (BMI < 25 kg/m2). With the exception of obese group, a significant difference was found between BMD and TBS reproducibility, being that of TBS slightly lower than BMD. A significant decrease of TBS values was found between normal and obese subjects, as well as between waist circumference groups. CONCLUSIONS: TBS precision error is not affected by BMI and waist circumference differences. TBS reproducibility showed to be slightly lower than that of BMD, but this difference was mitigated in obese patients. A negative association was found between the amount of fat mass and TBS mean values.
No
English
Dual-energy X-ray absorptiometry; Trabecular bone score; obesity; precision; reproducibility
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Articolo
Esperti anonimi
Pubblicazione scientifica
2019
Elsevier : Humana Press
22
3
359
366
8
Pubblicato
Periodico con rilevanza internazionale
pubmed
Aderisco
info:eu-repo/semantics/article
Fat Mass Does Not Increase the Precision Error of Trabecular Bone Score Measurements / C. Messina, C. Buonomenna, G. Menon, S. Magnani, D. Albano, S. Gitto, F.M. Ulivieri, L.M. Sconfienza. - In: JOURNAL OF CLINICAL DENSITOMETRY. - ISSN 1094-6950. - 22:3(2019), pp. 359-366. [10.1016/j.jocd.2019.01.001]
reserved
Prodotti della ricerca::01 - Articolo su periodico
8
262
Article (author)
no
C. Messina, C. Buonomenna, G. Menon, S. Magnani, D. Albano, S. Gitto, F.M. Ulivieri, L.M. Sconfienza
File in questo prodotto:
File Dimensione Formato  
messina2019.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 244.79 kB
Formato Adobe PDF
244.79 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/613885
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 17
social impact