BACKGROUND: Obesity is a major risk factor for several chronic diseases. The BioEnterics(®) Intragastric Balloon (BIB(®)) is used worldwide as a short-term (6 months) treatment in morbid obese patients. However, removal of BIB(®) past 6 months is a common occurrence in clinical practice often as a result of patient factors. The aim of the present Italian multicentre cohort study was to evaluate the safety and efficacy of the BIB(®) left in situ for more than 6 months. MATERIALS AND METHODS: A total of eight Italian centres participated in the study. Participating centres received a standardised questionnaire designed to capture safety and efficacy data. Weight loss data, as well as date, and reason for removal of the BIB(®) after 6 months were recorded. Adverse events, including mortality and complications, operators' subjective technical notes and findings, and difficulties during removal procedure were also collected. RESULTS: Six hundred and eleven patients were included. In the majority of cases, patient extended BIB(®) treatment due to satisfactory weight loss (44 %). At 6 months, all patients achieved a BMI statistically lower than the initial BMI (p < 0.001). There was a non-significant trend towards greater BMIL % in patients who underwent removal up to 15 months versus the results achieved up to 6 months. No major complications were recorded. CONCLUSION: Extending the duration of BIB(®) use up to 14 months safely maintains weight loss and satiety with greater results than that up to 6 months, without complications.

Intragastric balloon for obesity treatment : results of a multicentric evaluation for balloons left in place for more than 6 months / A. Genco, R. Maselli, F. Frangella, M. Cipriano, P. Forestieri, D. Delle Piane, F. Furbetta, G. Micheletto, F. Ciampaglia, P. Granelli, M. Zilli, M. Lorenzo, G. Di Rocco, D. Giannotti, A. Redler. - In: SURGICAL ENDOSCOPY. - ISSN 0930-2794. - 29:8(2015 Aug), pp. 2339-2343.

Intragastric balloon for obesity treatment : results of a multicentric evaluation for balloons left in place for more than 6 months

G. Micheletto;
2015

Abstract

BACKGROUND: Obesity is a major risk factor for several chronic diseases. The BioEnterics(®) Intragastric Balloon (BIB(®)) is used worldwide as a short-term (6 months) treatment in morbid obese patients. However, removal of BIB(®) past 6 months is a common occurrence in clinical practice often as a result of patient factors. The aim of the present Italian multicentre cohort study was to evaluate the safety and efficacy of the BIB(®) left in situ for more than 6 months. MATERIALS AND METHODS: A total of eight Italian centres participated in the study. Participating centres received a standardised questionnaire designed to capture safety and efficacy data. Weight loss data, as well as date, and reason for removal of the BIB(®) after 6 months were recorded. Adverse events, including mortality and complications, operators' subjective technical notes and findings, and difficulties during removal procedure were also collected. RESULTS: Six hundred and eleven patients were included. In the majority of cases, patient extended BIB(®) treatment due to satisfactory weight loss (44 %). At 6 months, all patients achieved a BMI statistically lower than the initial BMI (p < 0.001). There was a non-significant trend towards greater BMIL % in patients who underwent removal up to 15 months versus the results achieved up to 6 months. No major complications were recorded. CONCLUSION: Extending the duration of BIB(®) use up to 14 months safely maintains weight loss and satiety with greater results than that up to 6 months, without complications.
Intragastric balloon; BIB; Weight loss; Obesity management
Settore MED/18 - Chirurgia Generale
ago-2015
6-dic-2014
Article (author)
File in questo prodotto:
File Dimensione Formato  
intragastric ballon genco.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 552.78 kB
Formato Adobe PDF
552.78 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/611741
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
  • OpenAlex ND
social impact