BACKGROUND: Image-guided elastoplasty is an innovative method for percutaneous vertebral augmentation with a silicone elastomeric material. Our aim was to evaluate its technical success, safety and efficacy as well as the rate of secondary fractures. METHODS: Nineteen patients (13 women and 6 men, age 72 ± 10 years, mean ± standard deviation) underwent elastoplasty between 2010 and 2016. A total of 33 vertebrae were treated. A total of 2-6 mL of silicone-based elastomeric polymer material (VK100) was used. Visual analogue scale (VAS) and Oswestry disability index (ODI) pain scores were used. RESULTS: In all cases, it was possible to complete the procedure (technical success 100%). No major complications occurred. In 6/19 (31.5%) patients, asymptomatic leakage of the material was observed during the procedure. Full pain recovery was obtained in 18/19 (94%) patients. One patient with a painful angioma did not experience any change in symptoms. VAS and ODI were significantly reduced after the procedure, from 7.9 ± 1.1 to 0.7 ± 1.4 and from 79.6 ± 12% to 9.9 ± 14% respectively (p < 0.001 for both comparisons). After vertebroplasty, 14 of 15 patients (93%) removed the brace and 16/19 (84%) completely stopped using any drugs for pain relief (p < 0.001 for both pre-procedure versus post-procedure comparisons). At a mean follow-up time of 26.5 ± 28.1 months (median 8.7 months, range 6-69 months), no secondary fracture occurred. CONCLUSION: Taking into consideration the relatively small sample size, image-guided elastoplasty seems to be a safe procedure providing effective pain control over time.

Safety and results of image-guided vertebroplasty with elastomeric polymer material (elastoplasty) / G. Mauri, L. Nicosia, L.M. Sconfienza, G.M. Varano, P.D. Vigna, G. Bonomo, F. Orsi, C.G. Anselmetti. - In: EUROPEAN RADIOLOGY EXPERIMENTAL. - ISSN 2509-9280. - 2:1(2018 Oct 24). [10.1186/s41747-018-0062-5]

Safety and results of image-guided vertebroplasty with elastomeric polymer material (elastoplasty)

G. Mauri
Primo
;
L. Nicosia
Secondo
;
L.M. Sconfienza;
2018

Abstract

BACKGROUND: Image-guided elastoplasty is an innovative method for percutaneous vertebral augmentation with a silicone elastomeric material. Our aim was to evaluate its technical success, safety and efficacy as well as the rate of secondary fractures. METHODS: Nineteen patients (13 women and 6 men, age 72 ± 10 years, mean ± standard deviation) underwent elastoplasty between 2010 and 2016. A total of 33 vertebrae were treated. A total of 2-6 mL of silicone-based elastomeric polymer material (VK100) was used. Visual analogue scale (VAS) and Oswestry disability index (ODI) pain scores were used. RESULTS: In all cases, it was possible to complete the procedure (technical success 100%). No major complications occurred. In 6/19 (31.5%) patients, asymptomatic leakage of the material was observed during the procedure. Full pain recovery was obtained in 18/19 (94%) patients. One patient with a painful angioma did not experience any change in symptoms. VAS and ODI were significantly reduced after the procedure, from 7.9 ± 1.1 to 0.7 ± 1.4 and from 79.6 ± 12% to 9.9 ± 14% respectively (p < 0.001 for both comparisons). After vertebroplasty, 14 of 15 patients (93%) removed the brace and 16/19 (84%) completely stopped using any drugs for pain relief (p < 0.001 for both pre-procedure versus post-procedure comparisons). At a mean follow-up time of 26.5 ± 28.1 months (median 8.7 months, range 6-69 months), no secondary fracture occurred. CONCLUSION: Taking into consideration the relatively small sample size, image-guided elastoplasty seems to be a safe procedure providing effective pain control over time.
Pain; Pain management; Radiology (interventional); Silicone (elastomers); Vertebroplasty
Settore MED/36 - Diagnostica per Immagini e Radioterapia
24-ott-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
s41747-018-0062-5.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 826.24 kB
Formato Adobe PDF
826.24 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/597537
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact