Background.: The presence of patent foramen ovale (PFO) has been linked to many illness, including cryptogenic stroke, transient ischemic attack, migraine, platypnea-orthodeoxia syndrome and decompression sickness in scuba divers. Transesophageal echocardiography is the gold standard technique for the visualization of atrial septal anatomy, but it is a secondary level exam, not always available, with additional associated costs and not completely free from procedural risks. Standard transthoracic echocardiography (TTE) has a too low sensitivity for PFO screening.Purpose.: The aim of the study was to assess the role of TTE associated with agitated saline contrast injection (contrast-TTE) as a gatekeeper for the identification of PFO in a large cohort of patients undergoing selection for percutaneous closure.Methods.: A total of 200 patients undergoing a diagnostic work-up for the identification of PFO was imaged by contrast-TTE at rest and after provocative maneuvers (PM: Valsalva in all cases). Contrast TTE was graded from 0 to 4 on the bases of bubbles counting (0: no bubbles; 1: < 10 bubbles; 2: 10-30 bubbles; 3: >30 bubbles; 4: complete LV opacification). PFO closure was performed after a consensual clinical decision by the cardiologist and the neurologist taking into account comprehensive imaging, clinical evaluation and thrombophilia screening. PFO closure was always monitored by intracardiac echocardiography.Results.: At baseline contrast TTE was positive (≥2) in 34 patients (17%) while contrast TTE with PM was positive in 94 cases (47%). 27 out of 200 patients (14%) had an interatrial septal aneurysms. PFO closure was performed in 34 cases (17%). All of these had severe right-to-left shunting (≥3) at contrast TTE and 9 cases had also an interatrial septal aneurysms. The procedure was aborted in only 1 patient due to a complex defect anatomy.Conclusion.: Contrast TTE with PM may be not only considered an accurate tool for the detection of PFO but may be also inserted in the diagnostic work- up as a primary gatekeeper for percutaneous closure. Severe shunting at contrast TTE influences final decision making in a large cohort of cases undergoing screening for PFO closure.
Contrast transthoracic echocardiography as a gatekeeper for patent foramen ovale closure / M. Muratori, G. Italiano, E. Innocenti, L. Fusini, M. Mapelli, G. Tamborini, S. Ghulam Ali, P. Gripari, A. Maltagliati, F. Celeste, M. Pepi. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2412. - 17:2(2016), pp. ii109-ii110. (Intervento presentato al 20. convegno EUROECHO tenutosi a Leipzig nel 2016) [10.1093/ehjci/jew248.003].
Contrast transthoracic echocardiography as a gatekeeper for patent foramen ovale closure
G. Italiano;E. Innocenti;M. Mapelli;P. Gripari;
2016
Abstract
Background.: The presence of patent foramen ovale (PFO) has been linked to many illness, including cryptogenic stroke, transient ischemic attack, migraine, platypnea-orthodeoxia syndrome and decompression sickness in scuba divers. Transesophageal echocardiography is the gold standard technique for the visualization of atrial septal anatomy, but it is a secondary level exam, not always available, with additional associated costs and not completely free from procedural risks. Standard transthoracic echocardiography (TTE) has a too low sensitivity for PFO screening.Purpose.: The aim of the study was to assess the role of TTE associated with agitated saline contrast injection (contrast-TTE) as a gatekeeper for the identification of PFO in a large cohort of patients undergoing selection for percutaneous closure.Methods.: A total of 200 patients undergoing a diagnostic work-up for the identification of PFO was imaged by contrast-TTE at rest and after provocative maneuvers (PM: Valsalva in all cases). Contrast TTE was graded from 0 to 4 on the bases of bubbles counting (0: no bubbles; 1: < 10 bubbles; 2: 10-30 bubbles; 3: >30 bubbles; 4: complete LV opacification). PFO closure was performed after a consensual clinical decision by the cardiologist and the neurologist taking into account comprehensive imaging, clinical evaluation and thrombophilia screening. PFO closure was always monitored by intracardiac echocardiography.Results.: At baseline contrast TTE was positive (≥2) in 34 patients (17%) while contrast TTE with PM was positive in 94 cases (47%). 27 out of 200 patients (14%) had an interatrial septal aneurysms. PFO closure was performed in 34 cases (17%). All of these had severe right-to-left shunting (≥3) at contrast TTE and 9 cases had also an interatrial septal aneurysms. The procedure was aborted in only 1 patient due to a complex defect anatomy.Conclusion.: Contrast TTE with PM may be not only considered an accurate tool for the detection of PFO but may be also inserted in the diagnostic work- up as a primary gatekeeper for percutaneous closure. Severe shunting at contrast TTE influences final decision making in a large cohort of cases undergoing screening for PFO closure.File | Dimensione | Formato | |
---|---|---|---|
jew248.003.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.39 MB
Formato
Adobe PDF
|
1.39 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.