During soccer matches, performance decrements have been reported that relate to both physical abilities and technical skills. To investigate the effects of low-frequency electrical stimulation LFES (VeinoplusSport®, Ad Rem Technology, France) administered during half-time recovery on performance alterations during the second half. Twenty-two highly trained young players undertook a soccer-match simulation (SAFT90). During half-time, they were randomly assigned to LFES group or Placebo group. Each half was split into 3 bouts of 12 minutes. Following each bout, maximal strike speed (MSS), sprint test (ST), maximal sprint accelerations (MA) and metabolic power (MP) were determined in both groups. Arterial (AF) and venous flows (VF) were measured at rest and at the end of half-time. LEFS group exhibited beneficial effects on performance compared to the Placebo group with a likely effect for MSS, ST, MA, and a possible effect for MP. AF and VF increased statistically more in LEFS group compared to Placebo group. The use of specific calf-pump LFES during half-time of a youth simulated soccer match attenuated the decrease in performance during the second half compared to Placebo group. This effect is most marked at the beginning of the second half with regards to explosive parameters.

The effects of a calf pump device on second half performance of a simulated soccer match in competitive youth players / S. Beliard, J. Cassirame, G. Ennequin, G. Coratella, N. Tordi. - In: JOURNAL OF SPORTS SCIENCES. - ISSN 0264-0414. - 37:6(2019 Mar), pp. 708-716. [10.1080/02640414.2018.1522947]

The effects of a calf pump device on second half performance of a simulated soccer match in competitive youth players

G. Coratella
Penultimo
;
2019

Abstract

During soccer matches, performance decrements have been reported that relate to both physical abilities and technical skills. To investigate the effects of low-frequency electrical stimulation LFES (VeinoplusSport®, Ad Rem Technology, France) administered during half-time recovery on performance alterations during the second half. Twenty-two highly trained young players undertook a soccer-match simulation (SAFT90). During half-time, they were randomly assigned to LFES group or Placebo group. Each half was split into 3 bouts of 12 minutes. Following each bout, maximal strike speed (MSS), sprint test (ST), maximal sprint accelerations (MA) and metabolic power (MP) were determined in both groups. Arterial (AF) and venous flows (VF) were measured at rest and at the end of half-time. LEFS group exhibited beneficial effects on performance compared to the Placebo group with a likely effect for MSS, ST, MA, and a possible effect for MP. AF and VF increased statistically more in LEFS group compared to Placebo group. The use of specific calf-pump LFES during half-time of a youth simulated soccer match attenuated the decrease in performance during the second half compared to Placebo group. This effect is most marked at the beginning of the second half with regards to explosive parameters.
Low-frequency electrical stimulation; lower limb blood flow; performance; short−term recovery; soccer
Settore M-EDF/02 - Metodi e Didattiche delle Attivita' Sportive
mar-2019
4-ott-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
Beliard_2018_JSS.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.34 MB
Formato Adobe PDF
1.34 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/593723
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact