Background: Automatic photometric determination of the hemolysis index (HI) on serum and plasma samples is central to detect potential interferences of in vitro hemolysis on laboratory tests. When HI is above an established cut-off for interference, results may suffer from a significant bias and undermine clinical reliability of the test. Despite its undeniable importance for patient safety, the analytical performance of HI estimation is not usually checked in laboratories. Here we evaluated for the first time the random source of measurement uncertainty of HI determination on the two Abbott Architect c16000 platforms in use in our laboratory. Methods: From January 2016 to September 2017, we collected data from daily photometric determination of HI on a fresh-frozen serum pool with a predetermined HI value of ~100 (corresponding to ~1 g/L of free hemoglobin). Monthly and cumulative CVs were calculated. Results: During 21 months, 442 and 451 measurements were performed on the two platforms, respectively. Monthly CVs ranged from 0.7% to 2.7% on c16000–1 and from 0.8% to 2.5% on c16000-2, with a betweenplatform cumulative CV of 1.82% (corresponding to an expanded uncertainty of 3.64%). Mean HI values on the two platforms were just slightly biased (101.3 vs. 103.1, 1.76%), but, due to the high precision of measurements, this difference assumed statistical significance (p < 0.0001). Conclusions: Even though no quality specifications are available to date, our study shows that the HI measurement on Architect c16000 platform has nice reproducibility that could be considered in establishing the state of the art of the measurement.
Random uncertainty of photometric determination of hemolysis index on the Abbott Architect c16000 platform / E. Aloisio, A. Carnevale, S. Pasqualetti, S. Birindelli, A. Dolci, M. Panteghini. - In: CLINICAL BIOCHEMISTRY. - ISSN 0009-9120. - 57(2018), pp. 62-64. ((Intervento presentato al 11. convegno CIRME conference: Measurement uncertainty in medical laboratories: friend or foe? tenutosi a Milano nel 2017 [10.1016/j.clinbiochem.2018.01.009].
Random uncertainty of photometric determination of hemolysis index on the Abbott Architect c16000 platform
E. Aloisio
Primo
;A. DolciPenultimo
;M. PanteghiniUltimo
2018
Abstract
Background: Automatic photometric determination of the hemolysis index (HI) on serum and plasma samples is central to detect potential interferences of in vitro hemolysis on laboratory tests. When HI is above an established cut-off for interference, results may suffer from a significant bias and undermine clinical reliability of the test. Despite its undeniable importance for patient safety, the analytical performance of HI estimation is not usually checked in laboratories. Here we evaluated for the first time the random source of measurement uncertainty of HI determination on the two Abbott Architect c16000 platforms in use in our laboratory. Methods: From January 2016 to September 2017, we collected data from daily photometric determination of HI on a fresh-frozen serum pool with a predetermined HI value of ~100 (corresponding to ~1 g/L of free hemoglobin). Monthly and cumulative CVs were calculated. Results: During 21 months, 442 and 451 measurements were performed on the two platforms, respectively. Monthly CVs ranged from 0.7% to 2.7% on c16000–1 and from 0.8% to 2.5% on c16000-2, with a betweenplatform cumulative CV of 1.82% (corresponding to an expanded uncertainty of 3.64%). Mean HI values on the two platforms were just slightly biased (101.3 vs. 103.1, 1.76%), but, due to the high precision of measurements, this difference assumed statistical significance (p < 0.0001). Conclusions: Even though no quality specifications are available to date, our study shows that the HI measurement on Architect c16000 platform has nice reproducibility that could be considered in establishing the state of the art of the measurement.File | Dimensione | Formato | |
---|---|---|---|
Random uncertainty of photometric determination of hemolysis index.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
154.77 kB
Formato
Adobe PDF
|
154.77 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.