Introduction Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. In this study the accuracy of the dose delivered in SRS by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test using alanine pellets and gafchromic films. Methods Dose verifications were made using alanine dosimeters placed in an antropomorphic head phantom (Alderson Rando Phantom) under different treatment conditions in case of both single and multiple brain tumors. 1.25mm slice kVCT scan of the phantom was used to generate SRS plans on the TomoTherapy Planning Station platform. Commercial alanine dosimeters (Synergy Health, Germany) were irradiated in various positions of the phantom. EPR measurements were carried out through Bruker spectrometer at room temperature. Results The dose values for 6 different possible clinical scenarios characterized by the presence of one, two or three tumor lesions were reconstructed by means of alanine dosimeters and gafchromic films. The dose values measured through both experimental techniques show a good agreement with the dose values calculated by the TomoTherapy Treatment Planning System, for both tumors and organs at risk (such as optical chiasma and brain stem). Conclusion Alanine absolute dose measurements showed to be useful for the dosimetric validation of HT SRS treatments.
EPR/alanine dosimetry for verification in Helical Tomotherapy Stereotactic Radiosurgery (HT-SRS) treatments / S. Panzeca, G. Iacoviello, S. Gallo, G. Collura, T. Cucchiara, M. Marrale - In: The Joint International Symposium on EPR dosimetry and dating (EPR) and the International Conference on Biological Dosimetry (BioDose)[s.l] : The International Association of Biological and EPR Radiation Dosimetry (IABERD), 2018 Jun 12. - pp. 67-67 (( convegno EPRBioDose tenutosi a Monaco di Baviera nel 2018.
EPR/alanine dosimetry for verification in Helical Tomotherapy Stereotactic Radiosurgery (HT-SRS) treatments
S. GalloMembro del Collaboration Group
;
2018
Abstract
Introduction Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. In this study the accuracy of the dose delivered in SRS by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test using alanine pellets and gafchromic films. Methods Dose verifications were made using alanine dosimeters placed in an antropomorphic head phantom (Alderson Rando Phantom) under different treatment conditions in case of both single and multiple brain tumors. 1.25mm slice kVCT scan of the phantom was used to generate SRS plans on the TomoTherapy Planning Station platform. Commercial alanine dosimeters (Synergy Health, Germany) were irradiated in various positions of the phantom. EPR measurements were carried out through Bruker spectrometer at room temperature. Results The dose values for 6 different possible clinical scenarios characterized by the presence of one, two or three tumor lesions were reconstructed by means of alanine dosimeters and gafchromic films. The dose values measured through both experimental techniques show a good agreement with the dose values calculated by the TomoTherapy Treatment Planning System, for both tumors and organs at risk (such as optical chiasma and brain stem). Conclusion Alanine absolute dose measurements showed to be useful for the dosimetric validation of HT SRS treatments.File | Dimensione | Formato | |
---|---|---|---|
EPRBioDose2018_abstracts_Tomo.pdf
accesso riservato
Descrizione: Abstract
Tipologia:
Publisher's version/PDF
Dimensione
385.09 kB
Formato
Adobe PDF
|
385.09 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.