Undiagnosed esophageal intubation is still prominently in anesthesia-related morbidity and mortality. Three cases of undiagnosed esophageal intubation taken into consideration for possible anesthesiologic malpractice are presented. A review of the international anesthetic-related morbidity and mortality statistics indicates that this misadventure remains a problem even among anesthesia personnel, a medical population specifically trained in such a procedure. It is not only the frequency of this misadventure but the potential catastrophic consequences for the patient that underline the importance of being able to recognise and correct an esophageal intubation. The reliability of commonly prescribed methods of assessing tracheal tube position is reviewed and the conclusion is drawn that continuous end-tidal carbon dioxide measurement during anesthesia is perhaps the most reliable means under all circumstances for determining proper tube position and should be employed routinely whenever possible.

Incidenti anestesiologici da intubazione esofagea. Presentazione di tre casi clinici e valutazione medico-legale / E. Ronchi, C. Tommasino, L.O. Molendini, D. Lugani. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - 64:11(1998 Nov), pp. 521-528.

Incidenti anestesiologici da intubazione esofagea. Presentazione di tre casi clinici e valutazione medico-legale

C. Tommasino;
1998

Abstract

Undiagnosed esophageal intubation is still prominently in anesthesia-related morbidity and mortality. Three cases of undiagnosed esophageal intubation taken into consideration for possible anesthesiologic malpractice are presented. A review of the international anesthetic-related morbidity and mortality statistics indicates that this misadventure remains a problem even among anesthesia personnel, a medical population specifically trained in such a procedure. It is not only the frequency of this misadventure but the potential catastrophic consequences for the patient that underline the importance of being able to recognise and correct an esophageal intubation. The reliability of commonly prescribed methods of assessing tracheal tube position is reviewed and the conclusion is drawn that continuous end-tidal carbon dioxide measurement during anesthesia is perhaps the most reliable means under all circumstances for determining proper tube position and should be employed routinely whenever possible.
Adult; Esophagus; Female; Humans; Iatrogenic Disease; Intubation, Intratracheal; Italy; Male; Middle Aged; Respiratory Function Tests; Malpractice
Settore MED/41 - Anestesiologia
nov-1998
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/577742
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact