Objective: To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Materials and methods: Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between T2 relaxation times and body mass index (BMI) was tested using the Spearman’s rho. Results: Eighty sacroiliac joints of 40 subjects (mean age: 28 ± 4.8 years, range: 20–43; mean BMI: 23.3 ± 3.1, range: 18.9–30) were imaged. The mean T2 values obtained by the senior radiologist in the first series of measurements were 42 ± 4.4 ms, whereas in the second series were 40.7 ± 4.5 ms. The mean T2 values obtained by the radiology resident were 41.1 ± 4.2 ms. Intra-observer reproducibility was 88% (coefficient of repeatability = 3.8; bias = 1.28; p <.001), while inter-observer reproducibility was 86% (4.7; −.88; p <.001). There was significant association between sex and T2 relaxation times (p =.024) and significant inverse correlation between T2 relaxation times and BMI (r = −.340, p =.002). Conclusion: The assessment of T2 relaxation time measurements of sacroiliac joints seems to be highly reproducible at 1.5 T. Further studies could investigate the potential clinical application of this tool in the sacroiliac joints.

T2-mapping of the sacroiliac joints at 1.5 Tesla : A feasibility and reproducibility study / D. Albano, V. Chianca, R. Cuocolo, R. Bignone, F. Ciccia, L.M. Sconfienza, M. Midiri, A. Brunetti, R. Lagalla, M. Galia. - In: SKELETAL RADIOLOGY. - ISSN 0364-2348. - 47:12(2018 Dec 01), pp. 1691-1696. [10.1007/s00256-018-2951-3]

T2-mapping of the sacroiliac joints at 1.5 Tesla : A feasibility and reproducibility study

D. Albano
;
L.M. Sconfienza;
2018

Abstract

Objective: To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Materials and methods: Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between T2 relaxation times and body mass index (BMI) was tested using the Spearman’s rho. Results: Eighty sacroiliac joints of 40 subjects (mean age: 28 ± 4.8 years, range: 20–43; mean BMI: 23.3 ± 3.1, range: 18.9–30) were imaged. The mean T2 values obtained by the senior radiologist in the first series of measurements were 42 ± 4.4 ms, whereas in the second series were 40.7 ± 4.5 ms. The mean T2 values obtained by the radiology resident were 41.1 ± 4.2 ms. Intra-observer reproducibility was 88% (coefficient of repeatability = 3.8; bias = 1.28; p <.001), while inter-observer reproducibility was 86% (4.7; −.88; p <.001). There was significant association between sex and T2 relaxation times (p =.024) and significant inverse correlation between T2 relaxation times and BMI (r = −.340, p =.002). Conclusion: The assessment of T2 relaxation time measurements of sacroiliac joints seems to be highly reproducible at 1.5 T. Further studies could investigate the potential clinical application of this tool in the sacroiliac joints.
cartilage; magnetic resonance imaging; sacroiliac joint; T2 mapping
Settore MED/36 - Diagnostica per Immagini e Radioterapia
1-dic-2018
20-apr-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
10.1007-s00256-018-2951-3.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.67 MB
Formato Adobe PDF
1.67 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/571189
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 17
social impact