AIM: To compare the accuracy of whole-body magnetic resonance imaging (Wb-MRI) with diffusion-weighted imaging (DWI) to that of contrast-enhanced computed tomography (CE-CT) and 2-[(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG) positron-emission tomography co-registered with low dose-CT (PET-CT) in defining lymphoma disease stage. MATERIALS AND METHODS: From February 2010 to May 2014, 41 lymphoma patients underwent Wb-MRI-DWI, CE-CT, and (18)F-FDG PET-CT. Histological subtypes included aggressive B-cell (n=11), follicular (n=13), mantle cell (n=3), and Hodgkin's (n=14) lymphoma. To compare the procedures, the reference standard (RS) assessment was defined by combining the results from (18)F-FDG PET-CT, CE-CT, and bone marrow (BM) histology, modifications after therapy, and histological re-assessments of uncertain lesions. RESULTS: Among 1025 nodal sites, 217 had disease involvement according to the RS. CE-CT yielded 23 false-negative and 11 false-positive errors. Wb-MRI-DWI failed to recognise 17 localisations and had six false-positive errors; (18)F-FDG PET-CT had no errors. Among 458 extranodal sites, 37 were positive according to the RS. (18)F-FDG PET-CT yielded four false-negative and two false-positive results. CE-CT yielded 17 false-negative errors. Wb-MRI-DWI yielded a single false-negative error. Wb-MRI-DWI was the most reliable imaging technique for BM evaluation. Considering each procedure alone, the final stage would have been missed in four cases using (18)F-FDG PET-CT, 12 cases using CE-CT, and none using Wb-MRI-DWI. CONCLUSION: The present data support Wb-MRI-DWI as a sensitive and specific imaging technique for lymphoma evaluation, supporting its use in place of CE-CT for staging.
Whole-body MRI with diffusion-weighted imaging : A valuable alternative to contrast-enhanced CT for initial staging of aggressive lymphoma / A. Balbo-Mussetto, S. Cirillo, R. Bruna, A. Gueli, C. Saviolo, M. Petracchini, A. Fornari, C. Lario, D. Gottardi, A. De Crescenzo, C. Tarella. - In: CLINICAL RADIOLOGY. - ISSN 0009-9260. - 71:3(2016 Mar), pp. 271-279. [10.1016/j.crad.2015.11.018]
Whole-body MRI with diffusion-weighted imaging : A valuable alternative to contrast-enhanced CT for initial staging of aggressive lymphoma.
C. TarellaUltimo
2016
Abstract
AIM: To compare the accuracy of whole-body magnetic resonance imaging (Wb-MRI) with diffusion-weighted imaging (DWI) to that of contrast-enhanced computed tomography (CE-CT) and 2-[(18)F]-fluoro-2-deoxy-d-glucose ((18)F-FDG) positron-emission tomography co-registered with low dose-CT (PET-CT) in defining lymphoma disease stage. MATERIALS AND METHODS: From February 2010 to May 2014, 41 lymphoma patients underwent Wb-MRI-DWI, CE-CT, and (18)F-FDG PET-CT. Histological subtypes included aggressive B-cell (n=11), follicular (n=13), mantle cell (n=3), and Hodgkin's (n=14) lymphoma. To compare the procedures, the reference standard (RS) assessment was defined by combining the results from (18)F-FDG PET-CT, CE-CT, and bone marrow (BM) histology, modifications after therapy, and histological re-assessments of uncertain lesions. RESULTS: Among 1025 nodal sites, 217 had disease involvement according to the RS. CE-CT yielded 23 false-negative and 11 false-positive errors. Wb-MRI-DWI failed to recognise 17 localisations and had six false-positive errors; (18)F-FDG PET-CT had no errors. Among 458 extranodal sites, 37 were positive according to the RS. (18)F-FDG PET-CT yielded four false-negative and two false-positive results. CE-CT yielded 17 false-negative errors. Wb-MRI-DWI yielded a single false-negative error. Wb-MRI-DWI was the most reliable imaging technique for BM evaluation. Considering each procedure alone, the final stage would have been missed in four cases using (18)F-FDG PET-CT, 12 cases using CE-CT, and none using Wb-MRI-DWI. CONCLUSION: The present data support Wb-MRI-DWI as a sensitive and specific imaging technique for lymphoma evaluation, supporting its use in place of CE-CT for staging.| File | Dimensione | Formato | |
|---|---|---|---|
|
ClinicalRadiology_WholeBodyMRI_2016.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
960.14 kB
Formato
Adobe PDF
|
960.14 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




