In the present work, an integrated optofluidic chip for fluid viscosity measurements in the range from 1 mPas to 100 mPas is proposed. The device allows the use of small sample volumes (<1 mu L) and the measurement of viscosity as a function of temperature. Thanks to the precise control of the force exerted on dielectric spheres by optical beams, the viscosity of fluids is assessed by comparing the experimentally observed movement of dielectric beads produced by the optical forces with that expected by numerical calculations. The chip and the developed technique are validated by analyzing several fluids, such as Milli-Q water, ethanol and water-glycerol mixtures. The results show a good agreement between the experimental values and those reported in the literature. The extremely reduced volume of the sample required and the high flexibility of this technique make it a good candidate for measuring a wide range of viscosity values as well as for the analysis of nonlinear viscosity in complex fluids.

Integrated optofluidic chip for low-volume fluid viscosity measurement / T. Yang, G. Nava, V. Vitali, F. Bragheri, R. Osellame, T. Bellini, I. Cristiani, P. Minzioni. - In: MICROMACHINES. - ISSN 2072-666X. - 8:3(2017), pp. 65.1-65.11. [10.3390/mi8030065]

Integrated optofluidic chip for low-volume fluid viscosity measurement

G. Nava;T. Bellini;
2017

Abstract

In the present work, an integrated optofluidic chip for fluid viscosity measurements in the range from 1 mPas to 100 mPas is proposed. The device allows the use of small sample volumes (<1 mu L) and the measurement of viscosity as a function of temperature. Thanks to the precise control of the force exerted on dielectric spheres by optical beams, the viscosity of fluids is assessed by comparing the experimentally observed movement of dielectric beads produced by the optical forces with that expected by numerical calculations. The chip and the developed technique are validated by analyzing several fluids, such as Milli-Q water, ethanol and water-glycerol mixtures. The results show a good agreement between the experimental values and those reported in the literature. The extremely reduced volume of the sample required and the high flexibility of this technique make it a good candidate for measuring a wide range of viscosity values as well as for the analysis of nonlinear viscosity in complex fluids.
Microfluidics; Optical forces; Optical shooting; Optofluidics; Viscosity; Control and Systems Engineering; Mechanical Engineering; Electrical and Electronic Engineering
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore FIS/01 - Fisica Sperimentale
2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
micromachines-08-00065-v2.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 10.46 MB
Formato Adobe PDF
10.46 MB Adobe PDF Visualizza/Apri
micromachines-08-00065-v2.compressed.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 293.86 kB
Formato Adobe PDF
293.86 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/556672
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact