In this paper, we present a silicon photomultiplier (SiPM)-based photodetector module designed to readout large cerium-doped lanthanum bromide (LaBr3:Ce) scintillators (cylindrical 1 '' x 1 '' and 2 '' x 2 '') for nuclear physics experiments. The detector prototype has a modular structure and implements a real-time stabilization of the SiPM gain to compensate for the gain drift with temperature. The SiPM module consists of an array of 5 by 6 near-ultraviolet high-density SiPMs (Fondazione Bruno Kessler, Italy), each one having an active area of 6 mm x 6 mm and 30-mu m microcells. The single array is used for the 1 '' crystal readout, and it is assembled in a 2 x 2 format to read the 2 '' scintillator. Spectroscopic measurements were performed with both crystals. The 2 '' crystal was irradiated with different radioactive sources in an energy range between 122 keV and 1.3 MeV, and an energy resolution of 3.19 +/- 0.01% full-width at half-maximum (FWHM) has been achieved at 662 keV. The result is very close to the 3.07 +/- 0.03% FWHM measured with Super Bialkali photomultiplier tube (PMT) (Hamamatsu R6233-100) at the same energy with the same 2 '' crystal. In the framework of the comparison between SiPM and PMT for LaBr3:Ce readout, we provide an analysis of the energy resolution contributions based on the measurements performed with the developed gamma-ray detection system.

High-Resolution Gamma-Ray Spectroscopy with a SiPM-Based Detection Module for 1' and 2' LaBr3:Ce Readout / G. Cozzi, P. Busca, M. Carminati, C. Fiorini, G.L. Montagnani, F. Acerbi, A. Gola, G. Paternoster, C. Piemonte, V. Regazzoni, N. Blasi, F. Camera, B. Million. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 65:1(2018 Jan), pp. 8214215.645-8214215.655. [10.1109/TNS.2017.2784238]

High-Resolution Gamma-Ray Spectroscopy with a SiPM-Based Detection Module for 1' and 2' LaBr3:Ce Readout

F. Camera
Penultimo
;
2018

Abstract

In this paper, we present a silicon photomultiplier (SiPM)-based photodetector module designed to readout large cerium-doped lanthanum bromide (LaBr3:Ce) scintillators (cylindrical 1 '' x 1 '' and 2 '' x 2 '') for nuclear physics experiments. The detector prototype has a modular structure and implements a real-time stabilization of the SiPM gain to compensate for the gain drift with temperature. The SiPM module consists of an array of 5 by 6 near-ultraviolet high-density SiPMs (Fondazione Bruno Kessler, Italy), each one having an active area of 6 mm x 6 mm and 30-mu m microcells. The single array is used for the 1 '' crystal readout, and it is assembled in a 2 x 2 format to read the 2 '' scintillator. Spectroscopic measurements were performed with both crystals. The 2 '' crystal was irradiated with different radioactive sources in an energy range between 122 keV and 1.3 MeV, and an energy resolution of 3.19 +/- 0.01% full-width at half-maximum (FWHM) has been achieved at 662 keV. The result is very close to the 3.07 +/- 0.03% FWHM measured with Super Bialkali photomultiplier tube (PMT) (Hamamatsu R6233-100) at the same energy with the same 2 '' crystal. In the framework of the comparison between SiPM and PMT for LaBr3:Ce readout, we provide an analysis of the energy resolution contributions based on the measurements performed with the developed gamma-ray detection system.
No
English
Cerium-doped lanthanum bromide (LaBr3:ce); gamma-ray spectroscopy; nuclear physics; photomultiplier tube (PMT); silicon photomultiplier (SIPM)
Settore FIS/01 - Fisica Sperimentale
Articolo
Esperti anonimi
Pubblicazione scientifica
gen-2018
Institute of Electrical and Electronics Engineers
65
1
8214215
645
655
11
Pubblicato
Periodico con rilevanza internazionale
scopus
crossref
NON aderisco
info:eu-repo/semantics/article
High-Resolution Gamma-Ray Spectroscopy with a SiPM-Based Detection Module for 1' and 2' LaBr3:Ce Readout / G. Cozzi, P. Busca, M. Carminati, C. Fiorini, G.L. Montagnani, F. Acerbi, A. Gola, G. Paternoster, C. Piemonte, V. Regazzoni, N. Blasi, F. Camera, B. Million. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 65:1(2018 Jan), pp. 8214215.645-8214215.655. [10.1109/TNS.2017.2784238]
none
Prodotti della ricerca::01 - Articolo su periodico
13
262
Article (author)
Periodico con Impact Factor
G. Cozzi, P. Busca, M. Carminati, C. Fiorini, G.L. Montagnani, F. Acerbi, A. Gola, G. Paternoster, C. Piemonte, V. Regazzoni, N. Blasi, F. Camera, B. Million
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/555351
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 26
social impact