Purpose Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. MethodsThree fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV)+3mm in 2-view and ITV+5mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3mm and 5mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C9595%) were computed retrospectively. ResultsThe medianinterquartile-rage of C90 and C95 for upper lobe lesions was 99.10.6% and 99.0 +/- 3.1%, whereas they were 98.9 +/- 4.2% and 97.8 +/- 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C9595% in 70%, 85% and 63% of cases and C9590% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C9595% in 33%, 78% and 59% of cases, respectively. ConclusionsCTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins.

Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment / R. Ricotti, M. Seregni, D. Ciardo, S. Vigorito, E. Rondi, G. Piperno, A. Ferrari, M.A. Zerella, S. Arculeo, C.M. Francia, D. Sibio, F. Cattani, F. De Marinis, L. Spaggiari, R. Orecchia, M. Riboldi, G. Baroni, B.A. Jereczek-Fossa. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 45:4(2018 Apr), pp. 1360-1368. [10.1002/mp.12804]

Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment

M.A. Zerella;S. Arculeo;C.M. Francia;D. Sibio;L. Spaggiari;R. Orecchia;B.A. Jereczek-Fossa
Ultimo
2018

Abstract

Purpose Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. MethodsThree fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV)+3mm in 2-view and ITV+5mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3mm and 5mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C9595%) were computed retrospectively. ResultsThe medianinterquartile-rage of C90 and C95 for upper lobe lesions was 99.10.6% and 99.0 +/- 3.1%, whereas they were 98.9 +/- 4.2% and 97.8 +/- 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C9595% in 70%, 85% and 63% of cases and C9590% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C9595% in 33%, 78% and 59% of cases, respectively. ConclusionsCTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins.
LOT; CyberKnife; lung optimized treatment; lung stereotactic radiotherapy; margins; target coverage
Settore MED/36 - Diagnostica per Immagini e Radioterapia
apr-2018
12-feb-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
191-Ricotti-Evaluation of target coverage-Medical_Physics-2018.pdf

Open Access dal 23/06/2019

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 736.12 kB
Formato Adobe PDF
736.12 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/554664
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact