Purpose Post-implant CT-scanning is an essential part of permanent prostate brachytherapy. However, the evaluation of post-implant CT dosimetry is not straightforward due to the edema that can modify the dose to the prostate and to the organs at risk. The aim of this study is to evaluate the impact of the timing of the post-implant CT-scan on the dosimetric results and to verify if the Day 0 scan findings can predict Day 50 scanning. Methods 136 consecutive patients who received monotherapy with I-125 implants were selected for this study. Two sets of 8 dosimetric quality parameters corresponding to 2 different CT-scans (Day 0 and Day 50) were calculated and compared. The dosimetric parameters included are the percentage volume of the post-implant prostate receiving 80%, 100% and 150% of the prescribed dose, the doses covering 80% and 90% of the prostate volume and the Dose Homogeneity Index. The values of the dose covering 1 cm3of the rectum and urethra were assessed. Results All the dosimetric parameters of the Day 50 were higher than those of the Day 0 scan. Linear functions were obtained that calculate D90and V100values at Day 50 based on the Day 0 findings. Rectal and urethral parameters tended to be underestimated on Day 0 CT-scan relative to Day 50 based dosimetry. Conclusions Predicting the Day 50 dosimetry from the Day 0 scan could be a possible alternative to a Day 50 scan only in specific situations, but with a degree of uncertainty in the predicted values.

Can the Day 0 CT-scan predict the post-implant scanning? Results from 136 prostate cancer patients / F. Cattani, A. Vavassori, S. Comi, F. Gherardi, S. Russo, R. Orecchia, B.A. Jereczek-Fossa. - In: PHYSICA MEDICA. - ISSN 1120-1797. - 40(2017 Aug), pp. 66-71. [10.1016/j.ejmp.2017.07.011]

Can the Day 0 CT-scan predict the post-implant scanning? Results from 136 prostate cancer patients

R. Orecchia
Penultimo
;
B.A. Jereczek-Fossa
Ultimo
2017

Abstract

Purpose Post-implant CT-scanning is an essential part of permanent prostate brachytherapy. However, the evaluation of post-implant CT dosimetry is not straightforward due to the edema that can modify the dose to the prostate and to the organs at risk. The aim of this study is to evaluate the impact of the timing of the post-implant CT-scan on the dosimetric results and to verify if the Day 0 scan findings can predict Day 50 scanning. Methods 136 consecutive patients who received monotherapy with I-125 implants were selected for this study. Two sets of 8 dosimetric quality parameters corresponding to 2 different CT-scans (Day 0 and Day 50) were calculated and compared. The dosimetric parameters included are the percentage volume of the post-implant prostate receiving 80%, 100% and 150% of the prescribed dose, the doses covering 80% and 90% of the prostate volume and the Dose Homogeneity Index. The values of the dose covering 1 cm3of the rectum and urethra were assessed. Results All the dosimetric parameters of the Day 50 were higher than those of the Day 0 scan. Linear functions were obtained that calculate D90and V100values at Day 50 based on the Day 0 findings. Rectal and urethral parameters tended to be underestimated on Day 0 CT-scan relative to Day 50 based dosimetry. Conclusions Predicting the Day 50 dosimetry from the Day 0 scan could be a possible alternative to a Day 50 scan only in specific situations, but with a degree of uncertainty in the predicted values.
post-implant dosimetry; prostate brachytherapy; prostate edema; biophysics; radiology, nuclear medicine and imaging; physics and astronomy (all)
Settore MED/36 - Diagnostica per Immagini e Radioterapia
ago-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
177-Cattani-Can the day 0 CT-Phys Med-2017.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 639.46 kB
Formato Adobe PDF
639.46 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/552752
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact