Introduction: Complete AV block after combined fast pathway (FP) and slow pathway (SP) ablation is uncommon. The purpose of this study was to interrupt activation of these and additional inputs by placing a radiofrequency lesion across the interatrial septum between the FP and SP ablation sites. Methods and Results: In eight anesthetized open chest dogs, FP ablation induced significant A-H prolongation (Delta A-H: 51+/-14 msec; P < 0.001) and a shift of earliest retrograde atrial activation from the anterior septum to the region of the coronary sinus (CS) os. Subsequently, ablation of the interatrial septum across the fossa ovalis was successful in 5 of 8 dogs, changing the sequence of atrial activation (A) so that A at the His-bundle electrogram, which initially preceded A at the CS os (18 +/- 4 msec vs 46 +/- 7 msec, P < 0.01), now followed CS os A (81 +/- 31 msec vs 59 +/- 20 msec, P < 0.05). Additional ablation of the SP caused a type II Mobitz AV block or complete AV block in 5 of 8 dogs. The four dogs with complete AV block showed a stable, high junctional escape rhythm at a rate of 64 +/- 16 beats/min. Pacing between the ablation lesions and the AV node in one dog showed 1:1 AV conduction and Wenckebach-type AV block indicating preserved AV nodal function. Histology showed necrotic changes in the FP and SP transitional cell zones and in the atrial tissue of the interatrial septum. However, the compact AV node, His bundle, and adjacent atria and transitional cells were undamaged. Conclusion: There are additional AV nodal inputs in the interatrial septum in addition to the anterior FP and posterior SP inputs. Ablation of all of these may be required, if the aim is production of complete AV block proximal to the AV node with a high junctional escape rhythm.
Evidence for multiple atrio-AV nodal inputs in the normal dog heart / M. Antz, B..J. Scherlag, K. Otomo, J. Pitha, C. Tondo, E. Patterson, W..M. Jackman, R. Lazzara. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 9:4(1998 Apr), pp. 395-408. [10.1111/j.1540-8167.1998.tb00927.x]
Evidence for multiple atrio-AV nodal inputs in the normal dog heart
C. Tondo;
1998
Abstract
Introduction: Complete AV block after combined fast pathway (FP) and slow pathway (SP) ablation is uncommon. The purpose of this study was to interrupt activation of these and additional inputs by placing a radiofrequency lesion across the interatrial septum between the FP and SP ablation sites. Methods and Results: In eight anesthetized open chest dogs, FP ablation induced significant A-H prolongation (Delta A-H: 51+/-14 msec; P < 0.001) and a shift of earliest retrograde atrial activation from the anterior septum to the region of the coronary sinus (CS) os. Subsequently, ablation of the interatrial septum across the fossa ovalis was successful in 5 of 8 dogs, changing the sequence of atrial activation (A) so that A at the His-bundle electrogram, which initially preceded A at the CS os (18 +/- 4 msec vs 46 +/- 7 msec, P < 0.01), now followed CS os A (81 +/- 31 msec vs 59 +/- 20 msec, P < 0.05). Additional ablation of the SP caused a type II Mobitz AV block or complete AV block in 5 of 8 dogs. The four dogs with complete AV block showed a stable, high junctional escape rhythm at a rate of 64 +/- 16 beats/min. Pacing between the ablation lesions and the AV node in one dog showed 1:1 AV conduction and Wenckebach-type AV block indicating preserved AV nodal function. Histology showed necrotic changes in the FP and SP transitional cell zones and in the atrial tissue of the interatrial septum. However, the compact AV node, His bundle, and adjacent atria and transitional cells were undamaged. Conclusion: There are additional AV nodal inputs in the interatrial septum in addition to the anterior FP and posterior SP inputs. Ablation of all of these may be required, if the aim is production of complete AV block proximal to the AV node with a high junctional escape rhythm.File | Dimensione | Formato | |
---|---|---|---|
Evidence for multiple atrio AV nodal.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
4.39 MB
Formato
Adobe PDF
|
4.39 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.