Background: A novel catheter design (HD Mesh ablator, Bard) combining high-density circumferential mapping and direct radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). Objective: The purpose of this study was to assess the feasibility of the Mesh catheter for PV isolation in patients with paroxysmal atrial fibrillation (AF). Methods: Twenty consecutive patients (mean age 56.4 ± 12.2 years; 16 men) with paroxysmal drug-refractory AF were referred for ablation. The procedure was performed in a stepwise manner: PV isolation was initially attempted with the Mesh ablator, and if that was not successful, a conventional ablation approach was then used. Results: A total of 73 PVs including seven veins with left common ostium were targeted. Successful deployment of the Mesh was achieved in all but four veins (94.5%). Using the Mesh catheter for ablation, PV isolation was achieved in 46 (63%) of the 73 PVs. The mean (RF) ablation time required to achieve complete isolation was 12.4 ± 6.1 minutes per PV. The Mesh-only approach allowed isolation of all veins in eight (40%) patients. In combination with conventional ablation, successful PV isolation was achieved in 71 (97%) of 73 PVs. No complications attributable to the Mesh ablator occurred in this series. Conclusions: PV isolation using the Mesh catheter is feasible and may simplify the current PV isolation procedures. With the current catheter design, PV isolation could be achieved in 63% of PVs. A larger Mesh diameter with an over-the-wire design may help improve the acute success rate.

Initial experience with the Mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation / M. Moussa, F. Giovanni B., P. Augusto, H. E. Kevin, A. Andrea, L. Francesco, D.G. Piergiuseppe, B. Gianluigi, D.R. Antonio, M. Massimo, R. Jeremy N., C. Tondo. - In: HEART RHYTHM. - ISSN 1547-5271. - 5:11(2008), pp. 1510-1516.

Initial experience with the Mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation

C. Tondo
2008

Abstract

Background: A novel catheter design (HD Mesh ablator, Bard) combining high-density circumferential mapping and direct radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). Objective: The purpose of this study was to assess the feasibility of the Mesh catheter for PV isolation in patients with paroxysmal atrial fibrillation (AF). Methods: Twenty consecutive patients (mean age 56.4 ± 12.2 years; 16 men) with paroxysmal drug-refractory AF were referred for ablation. The procedure was performed in a stepwise manner: PV isolation was initially attempted with the Mesh ablator, and if that was not successful, a conventional ablation approach was then used. Results: A total of 73 PVs including seven veins with left common ostium were targeted. Successful deployment of the Mesh was achieved in all but four veins (94.5%). Using the Mesh catheter for ablation, PV isolation was achieved in 46 (63%) of the 73 PVs. The mean (RF) ablation time required to achieve complete isolation was 12.4 ± 6.1 minutes per PV. The Mesh-only approach allowed isolation of all veins in eight (40%) patients. In combination with conventional ablation, successful PV isolation was achieved in 71 (97%) of 73 PVs. No complications attributable to the Mesh ablator occurred in this series. Conclusions: PV isolation using the Mesh catheter is feasible and may simplify the current PV isolation procedures. With the current catheter design, PV isolation could be achieved in 63% of PVs. A larger Mesh diameter with an over-the-wire design may help improve the acute success rate.
Atrial fibrillation; Balloon catheter; Catheter ablation; Mesh ablator; Pulmonary vein isolation; Aged; Atrial Fibrillation; Catheter Ablation; Feasibility Studies; Female; Heart Conduction System; Humans; Male; Pulmonary Veins; Treatment Outcome; Cardiology and Cardiovascular Medicine; Physiology (medical)
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2008
Article (author)
File in questo prodotto:
File Dimensione Formato  
Initial experience with the Mesh catheter.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 3.01 MB
Formato Adobe PDF
3.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/540958
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 31
social impact