Atrial tachycardias are relatively common in patients with congenital heart disease. However, complex anomalies involving the heart and the great vessels might compromise the results of the ablation procedure. This report describes a clinical application of the new Cartosound⢠module as an adjunctive technology to understand the mechanism of the arrhythmia and to guide successfully the ablation in a complex anatomy. Isthmus-dependent atrial flutter was diagnosed in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation. Under these unusual circumstances, Cartosound facilitates interventional navigation within the right atrium and its adjacent structures and minimizes radiation exposure.
Real-time integration of intracardiac echocardiography and 3D electroanatomical mapping to guide catheter ablation of isthmus-dependent atrial flutter in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation / G.B. Forleo, A. Pappalardo, A. Avella, L. Visigalli, A. Dello Russo, C. Tondo. - In: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY. - ISSN 1383-875X. - 30:3(2011), pp. 273-277.
Real-time integration of intracardiac echocardiography and 3D electroanatomical mapping to guide catheter ablation of isthmus-dependent atrial flutter in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation
C. TondoUltimo
2011
Abstract
Atrial tachycardias are relatively common in patients with congenital heart disease. However, complex anomalies involving the heart and the great vessels might compromise the results of the ablation procedure. This report describes a clinical application of the new Cartosound⢠module as an adjunctive technology to understand the mechanism of the arrhythmia and to guide successfully the ablation in a complex anatomy. Isthmus-dependent atrial flutter was diagnosed in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation. Under these unusual circumstances, Cartosound facilitates interventional navigation within the right atrium and its adjacent structures and minimizes radiation exposure.File | Dimensione | Formato | |
---|---|---|---|
10.1007%2Fs10840-009-9427-2.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
430.88 kB
Formato
Adobe PDF
|
430.88 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.