Purpose In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). Material and methods Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI examination, performed from September 2008 to October 2013, was unremarkable. The local Ethical Committee approved this retrospective study. The ascending aorta was automatically identified on each phase of the cardiac cycle using a priori knowledge of aortic geometry. The frame that maximized the area, eccentricity, and solidity parameters was chosen for unsupervised initialization. Aortic segmentation was performed on each frame using active contouring without edges techniques. The entire algorithm was developed using Matlab R2016b. To validate the proposed method, the manual segmentation performed by a highly experienced operator was used. Dice similarity coefficient, Bland-Altman analysis, and Pearson's correlation coefficient were used as performance metrics. Results Comparing automated and manual segmentation of the aortic lumen on 714 images, Bland-Altman analysis showed a bias of − 6.68 mm2, a coefficient of repeatability of 91.22 mm2, a mean area measurement of 581.40 mm2, and a reproducibility of 85%. Automated and manual segmentation were highly correlated (R = 0.98). The Dice similarity coefficient versus the manual reference standard was 94.6 ± 2.1% (mean ± standard deviation). Conclusion A fully automated and robust method for identification and segmentation of ascending aorta on PC-MRI was developed. Its application on patients with a variety of pathologic conditions is advisable.

Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI / M. Codari, M. Scarabello, F. Secchi, C. Sforza, G. Baselli, F. Sardanelli. - In: MAGNETIC RESONANCE IMAGING. - ISSN 1873-5894. - 47(2018), pp. 77-82.

Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI

M. Codari
Primo
;
M. Scarabello;F. Secchi;C. Sforza;F. Sardanelli
Ultimo
2018

Abstract

Purpose In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). Material and methods Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI examination, performed from September 2008 to October 2013, was unremarkable. The local Ethical Committee approved this retrospective study. The ascending aorta was automatically identified on each phase of the cardiac cycle using a priori knowledge of aortic geometry. The frame that maximized the area, eccentricity, and solidity parameters was chosen for unsupervised initialization. Aortic segmentation was performed on each frame using active contouring without edges techniques. The entire algorithm was developed using Matlab R2016b. To validate the proposed method, the manual segmentation performed by a highly experienced operator was used. Dice similarity coefficient, Bland-Altman analysis, and Pearson's correlation coefficient were used as performance metrics. Results Comparing automated and manual segmentation of the aortic lumen on 714 images, Bland-Altman analysis showed a bias of − 6.68 mm2, a coefficient of repeatability of 91.22 mm2, a mean area measurement of 581.40 mm2, and a reproducibility of 85%. Automated and manual segmentation were highly correlated (R = 0.98). The Dice similarity coefficient versus the manual reference standard was 94.6 ± 2.1% (mean ± standard deviation). Conclusion A fully automated and robust method for identification and segmentation of ascending aorta on PC-MRI was developed. Its application on patients with a variety of pathologic conditions is advisable.
Aorta; Computer-assisted image processing; Magnetic resonance imaging
Settore BIO/16 - Anatomia Umana
Settore MED/36 - Diagnostica per Immagini e Radioterapia
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
2018
24-nov-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
codari_2017_MRI_1-s2.0-S0730725X17302679-main.pdf

accesso aperto

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
1-s2.0-S0730725X17302679-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 713.86 kB
Formato Adobe PDF
713.86 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/532736
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact