Objective/Background: Plaque protrusion through stent struts represents one of the principal causes of cerebral embolisation during carotid artery stenting (CAS) and the stent healing period. The aim of this study was to evaluate the safety (technical success) and efficacy (clinical success) of the CGuard stent system - a new nitinol stent covered by a closed-cell polyethylene terephthalate mesh designed to prevent embolic events. Methods: Eighty-two consecutive patients who underwent CAS with CGuard from June 2015 were included in this study. The same surgeon performed all procedures. Primary endpoints included technical and clinical success. Clinical success was considered to be absence of death, major or minor stroke. The incidence of new ischaemic brain lesions was also evaluated by diffusion weighted magnetic resonance imaging (DW-MRI) in a subgroup of patients as a secondary endpoint. Results: In this study, 82 patients (73.8 ± 8.5 years, 75% male, 19% symptomatic) underwent CAS procedures. Immediate technical success was 100%, with the stenosis diameter reduced from 81.4 ± 4.9% to 11.0 ± 3.5%. There was peri-operative technical and clinical success in 100% of symptomatic patients, and in 98.5% of asymptomatic patients, because of the occurrence of one acute stent thrombosis 4 hours post-CAS followed by a minor stroke. In the post-operative period (30 days), no new events were registered. The most recent 21 patients (24%) underwent DW-MRI in the peri-operative period: new ischaemic brain lesions were recorded in 23.8% of patients and the average lesion volume per patients was 0.039 ± 0.025 cm3. Conclusions: The technical and clinical outcomes of this single centre study suggest that the CGuard may be a safe and effective device for endovascular treatment of symptomatic and asymptomatic subjects, independent of aortic arch anatomy. Further larger comparative studies are needed to confirm these benefits.
Safety and Efficacy of the New Micromesh-Covered Stent CGuard in Patients Undergoing Carotid Artery Stenting: Early Experience From a Single Centre / C. Renato, T. Valerio, O. Andrea, M. Chiara, P. Aldo, F.M. Triulzi, V. Silani. - In: EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY. - ISSN 1078-5884. - (2017). [Epub ahead of print] [10.1016/j.ejvs.2017.09.015]
Safety and Efficacy of the New Micromesh-Covered Stent CGuard in Patients Undergoing Carotid Artery Stenting: Early Experience From a Single Centre
F.M. Triulzi;V. Silani
2017
Abstract
Objective/Background: Plaque protrusion through stent struts represents one of the principal causes of cerebral embolisation during carotid artery stenting (CAS) and the stent healing period. The aim of this study was to evaluate the safety (technical success) and efficacy (clinical success) of the CGuard stent system - a new nitinol stent covered by a closed-cell polyethylene terephthalate mesh designed to prevent embolic events. Methods: Eighty-two consecutive patients who underwent CAS with CGuard from June 2015 were included in this study. The same surgeon performed all procedures. Primary endpoints included technical and clinical success. Clinical success was considered to be absence of death, major or minor stroke. The incidence of new ischaemic brain lesions was also evaluated by diffusion weighted magnetic resonance imaging (DW-MRI) in a subgroup of patients as a secondary endpoint. Results: In this study, 82 patients (73.8 ± 8.5 years, 75% male, 19% symptomatic) underwent CAS procedures. Immediate technical success was 100%, with the stenosis diameter reduced from 81.4 ± 4.9% to 11.0 ± 3.5%. There was peri-operative technical and clinical success in 100% of symptomatic patients, and in 98.5% of asymptomatic patients, because of the occurrence of one acute stent thrombosis 4 hours post-CAS followed by a minor stroke. In the post-operative period (30 days), no new events were registered. The most recent 21 patients (24%) underwent DW-MRI in the peri-operative period: new ischaemic brain lesions were recorded in 23.8% of patients and the average lesion volume per patients was 0.039 ± 0.025 cm3. Conclusions: The technical and clinical outcomes of this single centre study suggest that the CGuard may be a safe and effective device for endovascular treatment of symptomatic and asymptomatic subjects, independent of aortic arch anatomy. Further larger comparative studies are needed to confirm these benefits.File | Dimensione | Formato | |
---|---|---|---|
Casana Eur J vasc Endosc Surg 2017.pdf
accesso riservato
Tipologia:
Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione
237.64 kB
Formato
Adobe PDF
|
237.64 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.