The time reconstruction performance of the ATLAS electromagnetic calorimeter readout is studied. The contribution of the electronics to the time resolution is estimated to be about 20 ps, thus demonstrating the possibility of achieving a small constant term in the time resolution for particles. The resolution to electromagnetic showers produced by an electron beam is also measured. After correction for the effects due to the calorimeter geometry, a 100 ps constant term is found for a typical cell.

Time resolution of the ATLAS barrel liquid argon electromagnetic calorimeter / M. Aharrouchea, J. Colas, L. Di Ciaccio, M. El Kacimia, O. Gaumera, M. Gouanère, D. Goujdami, R. Lafaye, S. Laplace, P. Perrodo, D. Prieur, H. Przysiezniak, G. Sauvage, F. Tarrade, I. Wingerter-Seez, R. Zitoun, F. Lanni, H. Ma, S. Rajagopalan, S. Rescia, H. Takai, A. Belymam, D. Benchekroun, M. Hakimi, A. Hoummada, R. Stroynowski, P. Zarzhitsky, J. Ye, M. Aleksae, J. Beck Hansen, T. Carli, P. Fassnacht, F. Gianotti, L. Hervas, W. Lampl, G. Unal, J. Collot, J.Y. Hostachy, F. Ledroit-Guillon, P. Martin, F. Malek, S. Viret, J. Ban, M. Leltchouk, J.A. Parsons, W. Sippach, D. Banfi, L. Carminati, D. Cavalli, G. Costa, M. Delmastro,M. Fanti, L. Mandelli, M. Mazzanti, G.F. Tartarelli, C. Bourdarios, L. Fayard, D. Fournier, G. Graziani, L. Iconomidou-Fayard, M. Kado, D. Lelas, M. Plamondon, L. Poggioli, P. Puzo, D. Rousseau, R. Sacco, L. Serin, S. Simion, D. Zerwas, A. Camard, D. Lacour, B. Laforge, I. Nikolic-Audit, Ph. Schwemling, W. Cleland, H. Ghazlane, R. Cherkaoui El Moursli, A. Idrissi Fakhr-Eddine, M. Boonekamp, N. Kerschen, B. Mansoulié, J.P. Meyer, J. Schwindling, B. Lund-Jensen. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 597:2-3(2008 Dec), pp. 178-188. [10.1016/j.nima.2008.08.142]

Time resolution of the ATLAS barrel liquid argon electromagnetic calorimeter

D. Banfi;L. Carminati;M. Fanti;L. Mandelli;
2008

Abstract

The time reconstruction performance of the ATLAS electromagnetic calorimeter readout is studied. The contribution of the electronics to the time resolution is estimated to be about 20 ps, thus demonstrating the possibility of achieving a small constant term in the time resolution for particles. The resolution to electromagnetic showers produced by an electron beam is also measured. After correction for the effects due to the calorimeter geometry, a 100 ps constant term is found for a typical cell.
Calorimeter ; electromagnetic showers ; electromagnetic ; calorimeter readout ; time resolution ; ATLAS ; liquid argon ; CERN LHC Coll
Settore FIS/01 - Fisica Sperimentale
Settore FIS/04 - Fisica Nucleare e Subnucleare
dic-2008
http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6TJM-4TG9HMM-1-1M&_cdi=5314&_user=107896&_orig=search&_coverDate=12%2F01%2F2008&_sk=994029997&view=c&wchp=dGLbVtz-zSkzk&md5=606b91269842aa321c700f2ee4e892f0&ie=/sdarticle.pdf
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/52343
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 11
social impact