At the PF1B cold neutron beam line at the Institut Laue Langevin, the EXILL array consisting of EXOGAM, GASP and ILL-Clover detectors was used to perform (n,gamma) measurements at very high coincidence rates. About ten different reactions were measured in autumn 2012 using a highly collimated cold neutron beam. In spring 2013, the EXOGAM array was combined with 16 LaBr3(Ce) scintillators in the EXILL&FATIMA campaign for the measurement of lifetimes using the generalised centroid difference method. We report on the properties of the set-ups and present first results from both campaigns.

The (n,gamma) campaigns at EXILL / J. Jolie, J.-M. Régis, D. Wilmsen, S. Ahmed, M. Pfeiffer, N. Saed-Samii, N. Warr, A. Blanc, M. Jentschel, U. Köster, P. Mutti, T. Soldner, G. Simpson, G. De France, W. Urban, F. Drouet, A. Vancraeyenest, P. Baczyk, M. Czerwinski, A. Korgul, C. Mazzocchi, T. Rzaca-Urban, A. Bruce, O.J. Roberts, L.M. Fraile, H. Mach, V. Paziy, A. Ignatov, S. Ilieva, T. Kröll, M. Scheck, M. Thürauf, D. Ivanova, S. Kisyov, S. Lalkovski, Z. Podolyák, P.H. Regan, W. Korten, M. Zielinska, M.D. Salsac, D. Habs, P.G. Thirolf, C.A. Ur, C. Bernards, R.F. Casten, N. Cooper, V. Werner, R.B. Cakirli, S. Leoni, G. Benzoni, G. Bocchi, S. Bottoni, F.C.L. Crespi, B. Fornal, N. Cieplicka, B. Szpak, C.M. Petrache, R. Leguillon, R. John, C. Lorenz, R. Massarczyk, R. Schwengner, D. Curien, R. Lozeva, L. Sengele, N. Marginean, R. Lica. - In: EPJ WEB OF CONFERENCES. - ISSN 2101-6275. - 93(2015), pp. 01014.1-01014.6. ((Intervento presentato al 15. convegno International Symposium on Capture Gamma Ray Spectroscopy and Related Topics tenutosi a Dresden nel 2014.

The (n,gamma) campaigns at EXILL

S. Leoni;G. Bocchi;S. Bottoni;F.C.L. Crespi;
2015

Abstract

At the PF1B cold neutron beam line at the Institut Laue Langevin, the EXILL array consisting of EXOGAM, GASP and ILL-Clover detectors was used to perform (n,gamma) measurements at very high coincidence rates. About ten different reactions were measured in autumn 2012 using a highly collimated cold neutron beam. In spring 2013, the EXOGAM array was combined with 16 LaBr3(Ce) scintillators in the EXILL&FATIMA campaign for the measurement of lifetimes using the generalised centroid difference method. We report on the properties of the set-ups and present first results from both campaigns.
excited-states; gamma; spectrometer; PT-196
Settore FIS/01 - Fisica Sperimentale
Settore FIS/04 - Fisica Nucleare e Subnucleare
Article (author)
File in questo prodotto:
File Dimensione Formato  
epjconf_cgs2015_01014.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.7 MB
Formato Adobe PDF
1.7 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Caricamento pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/2434/512114
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact