At the PF1B cold neutron beam line at the Institut Laue Langevin, the EXILL array consisting of EXOGAM, GASP and ILL-Clover detectors was used to perform (n,gamma) measurements at very high coincidence rates. About ten different reactions were measured in autumn 2012 using a highly collimated cold neutron beam. In spring 2013, the EXOGAM array was combined with 16 LaBr3(Ce) scintillators in the EXILL&FATIMA campaign for the measurement of lifetimes using the generalised centroid difference method. We report on the properties of the set-ups and present first results from both campaigns.
The (n,gamma) campaigns at EXILL / J. Jolie, J.M. Régis, D. Wilmsen, S. Ahmed, M. Pfeiffer, N. Saed Samii, N. Warr, A. Blanc, M. Jentschel, U. Köster, P. Mutti, T. Soldner, G. Simpson, G. De France, W. Urban, F. Drouet, A. Vancraeyenest, P. Baczyk, M. Czerwinski, A. Korgul, C. Mazzocchi, T. Rzaca Urban, A. Bruce, O.J. Roberts, L.M. Fraile, H. Mach, V. Paziy, A. Ignatov, S. Ilieva, T. Kröll, M. Scheck, M. Thürauf, D. Ivanova, S. Kisyov, S. Lalkovski, Z. Podolyák, P.H. Regan, W. Korten, M. Zielinska, M.D. Salsac, D. Habs, P.G. Thirolf, C.A. Ur, C. Bernards, R.F. Casten, N. Cooper, V. Werner, R.B. Cakirli, S. Leoni, G. Benzoni, G. Bocchi, S. Bottoni, F.C.L. Crespi, B. Fornal, N. Cieplicka, B. Szpak, C.M. Petrache, R. Leguillon, R. John, C. Lorenz, R. Massarczyk, R. Schwengner, D. Curien, R. Lozeva, L. Sengele, N. Marginean, R. Lica. - In: EPJ WEB OF CONFERENCES. - ISSN 2101-6275. - 93:(2015), pp. 01014.1-01014.6. (Intervento presentato al 15. convegno International Symposium on Capture Gamma Ray Spectroscopy and Related Topics tenutosi a Dresden nel 2014) [10.1051/epjconf/20159301014].
The (n,gamma) campaigns at EXILL
S. Leoni;G. Bocchi;S. Bottoni;F.C.L. Crespi;
2015
Abstract
At the PF1B cold neutron beam line at the Institut Laue Langevin, the EXILL array consisting of EXOGAM, GASP and ILL-Clover detectors was used to perform (n,gamma) measurements at very high coincidence rates. About ten different reactions were measured in autumn 2012 using a highly collimated cold neutron beam. In spring 2013, the EXOGAM array was combined with 16 LaBr3(Ce) scintillators in the EXILL&FATIMA campaign for the measurement of lifetimes using the generalised centroid difference method. We report on the properties of the set-ups and present first results from both campaigns.File | Dimensione | Formato | |
---|---|---|---|
epjconf_cgs2015_01014.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.7 MB
Formato
Adobe PDF
|
1.7 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.