The authors assessed the value of body mass index (BMI) correction of two electrocardiographic criteria in improving detection of left ventricular hypertrophy (LVH) and prediction of cardiovascular and all-cause mortality in the Italian study Pressioni Arteriose Monitorate E Loro Associazioni (PAMELA) population. At entry, 1549 patients underwent diagnostic tests, 24-hour ambulatory blood pressure (BP) monitoring, standard electrocardiography, and echocardiography. The BMI-corrected Cornell voltage and Sokolow-Lyon voltage criteria provided better results for detection of echocardiographic LVH as compared with unadjusted electrocardiographic parameters. Cornell voltage index, but not Sokolow-Lyon index, was associated with an increased risk of cardiovascular events (and all-cause mortality). The adjusted risk of cardiovascular events related to one-standard deviation increment of BMI-corrected Cornell voltage was similar to that conferred by the uncorrected criterion in the total population, but outperformed in obese participants. These findings show that correction for BMI may improve the diagnostic accuracy of Cornell voltage index in detecting LVH and prediction of cardiovascular mortality in obese individuals.
Does QRS Voltage Correction by Body Mass Index Improve the Accuracy of Electrocardiography in Detecting Left Ventricular Hypertrophy and Predicting Cardiovascular Events in a General Population? / C. Cuspidi, R. Facchetti, M. Bombelli, C. Sala, M. Tadic, G. Grassi, G. Mancia. - In: THE JOURNAL OF CLINICAL HYPERTENSION. - ISSN 1524-6175. - 18:5(2016), pp. 415-421. [10.1111/jch.12678]
Does QRS Voltage Correction by Body Mass Index Improve the Accuracy of Electrocardiography in Detecting Left Ventricular Hypertrophy and Predicting Cardiovascular Events in a General Population?
C. Sala;
2016
Abstract
The authors assessed the value of body mass index (BMI) correction of two electrocardiographic criteria in improving detection of left ventricular hypertrophy (LVH) and prediction of cardiovascular and all-cause mortality in the Italian study Pressioni Arteriose Monitorate E Loro Associazioni (PAMELA) population. At entry, 1549 patients underwent diagnostic tests, 24-hour ambulatory blood pressure (BP) monitoring, standard electrocardiography, and echocardiography. The BMI-corrected Cornell voltage and Sokolow-Lyon voltage criteria provided better results for detection of echocardiographic LVH as compared with unadjusted electrocardiographic parameters. Cornell voltage index, but not Sokolow-Lyon index, was associated with an increased risk of cardiovascular events (and all-cause mortality). The adjusted risk of cardiovascular events related to one-standard deviation increment of BMI-corrected Cornell voltage was similar to that conferred by the uncorrected criterion in the total population, but outperformed in obese participants. These findings show that correction for BMI may improve the diagnostic accuracy of Cornell voltage index in detecting LVH and prediction of cardiovascular mortality in obese individuals.File | Dimensione | Formato | |
---|---|---|---|
Cuspidi_et_al-2016-The_Journal_of_Clinical_Hypertension.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
266.78 kB
Formato
Adobe PDF
|
266.78 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.