AIMS: Scarce data are available on the long-term structural and functional changes of prosthetic valves after transcatheter aortic valve implantation (TAVI). The objective was to evaluate with echocardiography the long-term structural and functional changes of prosthetic valves after TAVI. METHODS AND RESULTS: Structural valve deterioration (SVD) was defined as leaflet thickening ≥3mm, presence of calcification and abnormal leaflet motion. Five-year echocardiographic follow-up was available in 96 out of 318 patients who underwent TAVI with a balloon-expandable device between April 2008 and December 2011. At 1-year follow-up, no patient showed SVD. At 5-year follow-up, SVD were observed in 29 (30%) patients who showed also a significant reduction of aortic valve area (AVA) together with an increase of mean and peak aortic pressure gradients at the latest echocardiography evaluation. Moreover, rate of central aortic valve regurgitation ≥2 was higher in SVD patients as compared to those without SVD, while there was no difference in terms of paravalvular regurgitation. Despite SVD, one patient only reached the criteria for severe stenosis and no reintervention was needed at 5-year follow-up. Variables independently associated with SVD were female sex, small body surface area, use of a 23 mm valve, and small AVA at pre-discharge echocardiogram. CONCLUSION: At 5-year follow-up, 30% of patients who underwent TAVI with a balloon-expandable valve showed initial SVD. However, SVD was not associated with severe stenosis in most of the patients and had no significant impact on and clinical outcome.

Five-year echocardiographic follow-up after TAVI: structural and functional changes of a balloon-expandable prosthetic aortic valve / M. Muratori, L. Fusini, G. Tamborini, P. Gripari, S. Ghulam Ali, M. Mapelli, F. Fabbiocchi, P. Trabattoni, M. Roberto, M. Agrifoglio, F. Alamanni, A. Bartorelli, M. Pepi. - In: EUROPEAN HEART JOURNAL. CARDIOVASCULAR IMAGING. - ISSN 2047-2404. - (2017). [Epub ahead of print]

Five-year echocardiographic follow-up after TAVI: structural and functional changes of a balloon-expandable prosthetic aortic valve

M. Mapelli;M. Agrifoglio;F. Alamanni;A. Bartorelli
Penultimo
;
2017

Abstract

AIMS: Scarce data are available on the long-term structural and functional changes of prosthetic valves after transcatheter aortic valve implantation (TAVI). The objective was to evaluate with echocardiography the long-term structural and functional changes of prosthetic valves after TAVI. METHODS AND RESULTS: Structural valve deterioration (SVD) was defined as leaflet thickening ≥3mm, presence of calcification and abnormal leaflet motion. Five-year echocardiographic follow-up was available in 96 out of 318 patients who underwent TAVI with a balloon-expandable device between April 2008 and December 2011. At 1-year follow-up, no patient showed SVD. At 5-year follow-up, SVD were observed in 29 (30%) patients who showed also a significant reduction of aortic valve area (AVA) together with an increase of mean and peak aortic pressure gradients at the latest echocardiography evaluation. Moreover, rate of central aortic valve regurgitation ≥2 was higher in SVD patients as compared to those without SVD, while there was no difference in terms of paravalvular regurgitation. Despite SVD, one patient only reached the criteria for severe stenosis and no reintervention was needed at 5-year follow-up. Variables independently associated with SVD were female sex, small body surface area, use of a 23 mm valve, and small AVA at pre-discharge echocardiogram. CONCLUSION: At 5-year follow-up, 30% of patients who underwent TAVI with a balloon-expandable valve showed initial SVD. However, SVD was not associated with severe stenosis in most of the patients and had no significant impact on and clinical outcome.
TAVI ; echocardiography; structural valve deterioration
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
2017
30-mar-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
inpress-EHJim-5Y echo follow-up after TAVI.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 600.09 kB
Formato Adobe PDF
600.09 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/489755
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 14
social impact