BACKGROUND: Guidelines for diagnosing acute myocardial infarction (AMI) recommend adding kinetic changes to the initial cardiac troponin (cTn) blood concentration to improve AMI diagnosis. We hypothesized that kinetic changes may not be required in patients presenting with highly abnormal cTn. METHODS: Patients presenting with suspected AMI to the emergency department were enrolled in a prospective diagnostic study. We assessed the positive predictive value (PPV) of initial high-sensitivity cardiac troponin T (hs-cTnT) blood concentrations alone and in combination with kinetic changes for AMI. Predefined relative changes ( change of 20%) and absolute changes (change 9.2 ng/L) within different time intervals (1h, 2 h, and 4 –14 h after presentation) were assessed. The final diagnosis was adjudicated by 2 independent cardiologists. RESULTS: Among 1282 patients, 213 (16.6%) patients had a final diagnosis of AMI. For AMI prediction, PPVs increased from 48.8% for an initial hs-cTnT 14 ng/L to 87.2% for 60 ng/L, whereas PPVs remained unchanged for higher hs-cTnT concentrations at baseline (87.1% for both 80 ng/L and 100 ng/L). With addition of 20% relative change, PPVs were not further improve improved in patients with baseline hs-cTnT 80 ng/L using the 1-h (84.0%) and 2-h (88.9%) intervals, and only minimally when extending the interval to 4 –14 h (91.2% for 80 ng/L and 90.4% for 100 ng/L, respectively). Similar findings were observed when applying absolute changes. CONCLUSIONS: In chest pain patients with highly abnormal hs-cTnT concentrations at presentation, subsequent blood draws may not be required, as they do not provide incremental diagnostic value for prediction of AMI diagnosis.
Serial Sampling of High-Sensitivity Cardiac Troponin T May Not Be Required for Prediction of Acute Myocardial Infarction Diagnosis in Chest Pain Patients with Highly Abnormal Concentrations at Presentation / M. Mueller Hennessen, C. Mueller, E. Giannitsis, M. Biener, M. Vafaie, C.R. de Filippi, M. Christ, J. Ordóñez Llanos, M. Panteghini, M. Plebani, F. Verschuren, D. Melki, J.K. French, R.H. Christenson, R. Body, J. Mccord, C. Dinkel, H.A. Katus, B. Lindahl. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 63:2(2017), pp. 542-551. [10.1373/clinchem.2016.258392]
Serial Sampling of High-Sensitivity Cardiac Troponin T May Not Be Required for Prediction of Acute Myocardial Infarction Diagnosis in Chest Pain Patients with Highly Abnormal Concentrations at Presentation
M. Panteghini;
2017
Abstract
BACKGROUND: Guidelines for diagnosing acute myocardial infarction (AMI) recommend adding kinetic changes to the initial cardiac troponin (cTn) blood concentration to improve AMI diagnosis. We hypothesized that kinetic changes may not be required in patients presenting with highly abnormal cTn. METHODS: Patients presenting with suspected AMI to the emergency department were enrolled in a prospective diagnostic study. We assessed the positive predictive value (PPV) of initial high-sensitivity cardiac troponin T (hs-cTnT) blood concentrations alone and in combination with kinetic changes for AMI. Predefined relative changes ( change of 20%) and absolute changes (change 9.2 ng/L) within different time intervals (1h, 2 h, and 4 –14 h after presentation) were assessed. The final diagnosis was adjudicated by 2 independent cardiologists. RESULTS: Among 1282 patients, 213 (16.6%) patients had a final diagnosis of AMI. For AMI prediction, PPVs increased from 48.8% for an initial hs-cTnT 14 ng/L to 87.2% for 60 ng/L, whereas PPVs remained unchanged for higher hs-cTnT concentrations at baseline (87.1% for both 80 ng/L and 100 ng/L). With addition of 20% relative change, PPVs were not further improve improved in patients with baseline hs-cTnT 80 ng/L using the 1-h (84.0%) and 2-h (88.9%) intervals, and only minimally when extending the interval to 4 –14 h (91.2% for 80 ng/L and 90.4% for 100 ng/L, respectively). Similar findings were observed when applying absolute changes. CONCLUSIONS: In chest pain patients with highly abnormal hs-cTnT concentrations at presentation, subsequent blood draws may not be required, as they do not provide incremental diagnostic value for prediction of AMI diagnosis.File | Dimensione | Formato | |
---|---|---|---|
Serial Sampling of High-Sensitivity Cardiac Troponin T.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
463.15 kB
Formato
Adobe PDF
|
463.15 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.