Urine represents a valuable biofluid for noninvasive measurement of Human Growth Hormone (HGH) secretion. Unfortunately, currently available commercial HGH immunoassays do not achieve the sensitivity needed for urinary HGH measurement in the low picogram per milliliter range, the expected normal concentration range of HGH in urine. A nanotechnology based sample preprocessing step was used to extract and concentrate HGH in urine so that urinary HGH could be measured with a clinical grade standard immunoassay designed for serum (Immulite 1000, Siemens). We applied the nanoparticle enhanced immunoassay to evaluate the baseline value of urinary HGH in a population of healthy young adults (age 18-30, N=33, median 21, M: F=39%:61%, with no reported medical therapies). Nanoparticle sample preprocessing effectively improved the lower limit of detection of the Immulite HGH assay by more than 50 fold, shifting the linear range of the assay to encompass the expected value of urinary HGH. The full process between run and within run CV% was 7.9 and 9.0%, respectively. On 33 healthy volunteers, the 95% reference values for hGH in spot urine normalized to specific gravity were 0.64 - 16.85 pg/mL (0.05-5.82 ng/g creatinine). Nanoparticle preprocessing constitutes a reliable means of measuring urinary HGH with a clinical grade immunoassay, now establishing a normal baseline value for HGH in urine. Nanoparticles can be used to study the kinetics of HGH excretion in urine, and the factors that influence urinary HGH secretion and HGH isoform proportions.

Application of analyte harvesting nanoparticle technology to the measurement of urinary HGH in healthy individuals / A. Luchini, D. Tamburro, R. Magni, C. Fredolini, V. Espina, J. Bosch, E. Garaci, E.F. Petricoin, L.A. Liotta. - In: JOURNAL OF SPORTS MEDICINE & DOPING STUDIES. - ISSN 2161-0673. - 2:6(2012), pp. 116.1-116.4. [10.4172/2161-0673.1000116]

Application of analyte harvesting nanoparticle technology to the measurement of urinary HGH in healthy individuals

R. Magni;
2012

Abstract

Urine represents a valuable biofluid for noninvasive measurement of Human Growth Hormone (HGH) secretion. Unfortunately, currently available commercial HGH immunoassays do not achieve the sensitivity needed for urinary HGH measurement in the low picogram per milliliter range, the expected normal concentration range of HGH in urine. A nanotechnology based sample preprocessing step was used to extract and concentrate HGH in urine so that urinary HGH could be measured with a clinical grade standard immunoassay designed for serum (Immulite 1000, Siemens). We applied the nanoparticle enhanced immunoassay to evaluate the baseline value of urinary HGH in a population of healthy young adults (age 18-30, N=33, median 21, M: F=39%:61%, with no reported medical therapies). Nanoparticle sample preprocessing effectively improved the lower limit of detection of the Immulite HGH assay by more than 50 fold, shifting the linear range of the assay to encompass the expected value of urinary HGH. The full process between run and within run CV% was 7.9 and 9.0%, respectively. On 33 healthy volunteers, the 95% reference values for hGH in spot urine normalized to specific gravity were 0.64 - 16.85 pg/mL (0.05-5.82 ng/g creatinine). Nanoparticle preprocessing constitutes a reliable means of measuring urinary HGH with a clinical grade immunoassay, now establishing a normal baseline value for HGH in urine. Nanoparticles can be used to study the kinetics of HGH excretion in urine, and the factors that influence urinary HGH secretion and HGH isoform proportions.
human growth hormone; immunoassay; nanoparticles; reference values; urine
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
application-of-analyte-harvesting-nanoparticle-technology-to-the-measurement-of-urinary-hgh-in--healthy-individuals-2161-0673.1000116.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 968.97 kB
Formato Adobe PDF
968.97 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/470090
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact