Objectives: To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. Methods: An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Results: Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94–97%) [laser=98% (95–99%); HIFU=96% (90–98%); radiofrequency=96% (93–97%); cryoablation=95% (90–98%); microwave=93% (81–98%)]. Pooled technique efficacy was 75% (67–81%) [radiofrequency=82% (74–88); cryoablation=75% (51–90); laser=59% (35–79); HIFU=49% (26–74)]. Major complications pooled rate was 6% (4–8). Minor complications pooled rate was 8% (5–13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Conclusions: Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. Key Points: • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6–8%).

Technical success, technique efficacy and complications of minimally-invasive imaging-guided percutaneous ablation procedures of breast cancer: a systematic review and meta-analysis / G. Mauri, L.M. Sconfienza, L.C. Pescatori, M.P. Fedeli, M. Alì, G. Di Leo, F. Sardanelli. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - (2017). [Epub ahead of print] [10.1007/s00330-016-4668-9]

Technical success, technique efficacy and complications of minimally-invasive imaging-guided percutaneous ablation procedures of breast cancer: a systematic review and meta-analysis

G. Mauri
;
L.M. Sconfienza
Secondo
;
L.C. Pescatori;M.P. Fedeli;M. Alì;F. Sardanelli
Ultimo
2017

Abstract

Objectives: To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. Methods: An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Results: Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94–97%) [laser=98% (95–99%); HIFU=96% (90–98%); radiofrequency=96% (93–97%); cryoablation=95% (90–98%); microwave=93% (81–98%)]. Pooled technique efficacy was 75% (67–81%) [radiofrequency=82% (74–88); cryoablation=75% (51–90); laser=59% (35–79); HIFU=49% (26–74)]. Major complications pooled rate was 6% (4–8). Minor complications pooled rate was 8% (5–13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Conclusions: Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. Key Points: • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6–8%).
Breast cancer; Meta-analysis; Minimally-invasive treatment; Systematic review; Thermal ablation
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2017
3-gen-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs00330-016-4668-9.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/469566
Citazioni
  • ???jsp.display-item.citation.pmc??? 24
  • Scopus 66
  • ???jsp.display-item.citation.isi??? 62
social impact