Background The outcome of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) has improved thanks to left atrium (LA) anatomy reconstruction by cardiac computed tomography (CCT). A new model-based iterative reconstruction algorithm (MBIR) provides image noise reduction achieving effective radiation dose (ED) close to chest X-ray exposure. Aim of this study was comparing RFCA procedural characteristics, AF recurrence and radiation exposure between patients in whom RFCA was guided by CCT image integration with MBIR versus a CCT standard protocol. Methods Three-hundred consecutive patients with drug-refractory AF were studied with CCT using MBIR (Group 1; N:150) or CCT with standard protocol (Group 2; N:150) for LA evaluation and treated by image integration-supported RFCA. Image noise, signal to noise ratio (SNR), contrast to noise ratio (CNR), RFCA procedural characteristics, rate of AF recurrence and radiation exposure were compared. Results Group 1 showed higher SNR (25.9 ± 7.1 vs. 16.2 ± 4.8, p < 0.001) and CNR (23.3 ± 7.1 vs. 12.2 ± 4.2, p < 0.001) and lower image noise (22.3 ± 5.2 vs. 32.6 ± 8.1 HU, p < 0.001), fluoroscopy time (21 ± 12 vs. 29 ± 15 min, p < 0.01) and procedural duration (135 ± 89 vs. 172 ± 55, p < 0.001). Group 1 showed a 94% reduction of ED as compared to Group 2 (CCT-ED related: 0.41 ± 0.04 vs. 6.17 ± 4.11 mSv, p < 0.001; cumulative CCT + RFCA-ED related: 21.9 ± 17.9 vs. 36.0 ± 24.1 mSv, p < 0.001) with similar rate of AF recurrence (25% vs. 29%, p = 0.437). Conclusions CCT with MBIR allows accurate reconstruction of LA anatomy in AF patients undergoing RFCA with a sub-millisievert ED and comparable success rate of RFCA as compared to a standard CCT scan protocol.

Left atrium and pulmonary vein imaging using sub-millisiviert cardiac computed tomography: Impact on radiofrequency catheter ablation cumulative radiation exposure and outcome in atrial fibrillation patients / G. Pontone, D. Andreini, M. Petulla, A. Annoni, A.I. Guaricci, E. Innocenti, E. Russo, M. Guglielmo, S. Mushtaq, A. Baggiano, V. Beltrama, L. Fusini, C. Segurini, E. Conte, A. Formenti, G. Fassini, S. Riva, C. Tondo, P. Agostoni, A.L. Bartorelli, M. Pepi. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 228(2017 Feb), pp. 805-811. [10.1016/j.ijcard.2016.11.203]

Left atrium and pulmonary vein imaging using sub-millisiviert cardiac computed tomography: Impact on radiofrequency catheter ablation cumulative radiation exposure and outcome in atrial fibrillation patients

G. Pontone;D. Andreini;A. Annoni;E. Innocenti;S. Mushtaq;A. Baggiano;L. Fusini;C. Segurini;E. Conte;A. Formenti;C. Tondo;P. Agostoni;A.L. Bartorelli;
2017

Abstract

Background The outcome of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) has improved thanks to left atrium (LA) anatomy reconstruction by cardiac computed tomography (CCT). A new model-based iterative reconstruction algorithm (MBIR) provides image noise reduction achieving effective radiation dose (ED) close to chest X-ray exposure. Aim of this study was comparing RFCA procedural characteristics, AF recurrence and radiation exposure between patients in whom RFCA was guided by CCT image integration with MBIR versus a CCT standard protocol. Methods Three-hundred consecutive patients with drug-refractory AF were studied with CCT using MBIR (Group 1; N:150) or CCT with standard protocol (Group 2; N:150) for LA evaluation and treated by image integration-supported RFCA. Image noise, signal to noise ratio (SNR), contrast to noise ratio (CNR), RFCA procedural characteristics, rate of AF recurrence and radiation exposure were compared. Results Group 1 showed higher SNR (25.9 ± 7.1 vs. 16.2 ± 4.8, p < 0.001) and CNR (23.3 ± 7.1 vs. 12.2 ± 4.2, p < 0.001) and lower image noise (22.3 ± 5.2 vs. 32.6 ± 8.1 HU, p < 0.001), fluoroscopy time (21 ± 12 vs. 29 ± 15 min, p < 0.01) and procedural duration (135 ± 89 vs. 172 ± 55, p < 0.001). Group 1 showed a 94% reduction of ED as compared to Group 2 (CCT-ED related: 0.41 ± 0.04 vs. 6.17 ± 4.11 mSv, p < 0.001; cumulative CCT + RFCA-ED related: 21.9 ± 17.9 vs. 36.0 ± 24.1 mSv, p < 0.001) with similar rate of AF recurrence (25% vs. 29%, p = 0.437). Conclusions CCT with MBIR allows accurate reconstruction of LA anatomy in AF patients undergoing RFCA with a sub-millisievert ED and comparable success rate of RFCA as compared to a standard CCT scan protocol.
No
English
ablation; atrial fibrillation; iterative reconstruction algorithm; outcome; radiation exposure; medicine (all); cardiology and cardiovascular medicine
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
feb-2017
Elsevier
228
805
811
7
Pubblicato
Periodico con rilevanza internazionale
www.elsevier.com/locate/ijcard
scopus
crossref
pubmed
Aderisco
info:eu-repo/semantics/article
Left atrium and pulmonary vein imaging using sub-millisiviert cardiac computed tomography: Impact on radiofrequency catheter ablation cumulative radiation exposure and outcome in atrial fibrillation patients / G. Pontone, D. Andreini, M. Petulla, A. Annoni, A.I. Guaricci, E. Innocenti, E. Russo, M. Guglielmo, S. Mushtaq, A. Baggiano, V. Beltrama, L. Fusini, C. Segurini, E. Conte, A. Formenti, G. Fassini, S. Riva, C. Tondo, P. Agostoni, A.L. Bartorelli, M. Pepi. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 228(2017 Feb), pp. 805-811. [10.1016/j.ijcard.2016.11.203]
reserved
Prodotti della ricerca::01 - Articolo su periodico
21
262
Article (author)
no
G. Pontone, D. Andreini, M. Petulla, A. Annoni, A.I. Guaricci, E. Innocenti, E. Russo, M. Guglielmo, S. Mushtaq, A. Baggiano, V. Beltrama, L. Fusini, ...espandi
File in questo prodotto:
File Dimensione Formato  
agostoni 1.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 607.56 kB
Formato Adobe PDF
607.56 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/466157
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact