Background: Serum cortisol concentration is often measured in dogs for the diagnosis and monitoring of adrenal disease. An enzyme-linked fluorescent assay (VIDAS method) on the MiniVidas analyzer has been validated for the measurement of cortisol concentration in human serum and could have applications for canine samples. Objective: The aim of this study was to compare canine cortisol results obtained using the VIDAS method with those obtained using the IMMULITE-2000 immunoassay, which has previously been validated for canine serum. Methods: The concentration of cortisol in 40 canine serum samples was determined concurrently with the VIDAS and IMMULITE methods, the latter as the reference method. Pearson's correlation coefficient, linear, and Deming regression analyses and Bland-Altman analysis were used to compare the 2 methods. Acceptability of the new method was judged using a medical decision chart (MEDx chart). Results: Cortisol concentrations obtained with the IMMULITE method ranged from 23.1 to 1380 nmol/L. Correlation (r =.977) and simple linear regression (slope = 1.0722, confidence interval [CI] 0.996-1.148; intercept =-4.799, CI -42.838 to 33.240) revealed no proportional or constant error. Based on Deming regression and a Bland-Altman plot the 2 methods gave comparable results. The MEDx chart indicated that performance of the new method was good at decision limits of 40, 132, and 480 nmol/L. Conclusion: Results of the VIDAS method were comparable to those of the IMMULITE-2000 reference method such that the VIDAS may be used as an alternative assay to evaluate serum cortisol concentration in dogs for the diagnosis of adrenal dis

Comparison of the VIDAS and IMMULITE-2000 methods for cortisol measurement in canine serum / D. Proverbio, D. Groppetti, E. Spada, R. Perego. - In: VETERINARY CLINICAL PATHOLOGY. - ISSN 0275-6382. - 38:3(2009 Sep), pp. 332-336. [10.1111/j.1939-165X.2009.00135.x]

Comparison of the VIDAS and IMMULITE-2000 methods for cortisol measurement in canine serum

D. Proverbio
Primo
;
D. Groppetti
Secondo
;
E. Spada
Penultimo
;
R. Perego
Ultimo
2009

Abstract

Background: Serum cortisol concentration is often measured in dogs for the diagnosis and monitoring of adrenal disease. An enzyme-linked fluorescent assay (VIDAS method) on the MiniVidas analyzer has been validated for the measurement of cortisol concentration in human serum and could have applications for canine samples. Objective: The aim of this study was to compare canine cortisol results obtained using the VIDAS method with those obtained using the IMMULITE-2000 immunoassay, which has previously been validated for canine serum. Methods: The concentration of cortisol in 40 canine serum samples was determined concurrently with the VIDAS and IMMULITE methods, the latter as the reference method. Pearson's correlation coefficient, linear, and Deming regression analyses and Bland-Altman analysis were used to compare the 2 methods. Acceptability of the new method was judged using a medical decision chart (MEDx chart). Results: Cortisol concentrations obtained with the IMMULITE method ranged from 23.1 to 1380 nmol/L. Correlation (r =.977) and simple linear regression (slope = 1.0722, confidence interval [CI] 0.996-1.148; intercept =-4.799, CI -42.838 to 33.240) revealed no proportional or constant error. Based on Deming regression and a Bland-Altman plot the 2 methods gave comparable results. The MEDx chart indicated that performance of the new method was good at decision limits of 40, 132, and 480 nmol/L. Conclusion: Results of the VIDAS method were comparable to those of the IMMULITE-2000 reference method such that the VIDAS may be used as an alternative assay to evaluate serum cortisol concentration in dogs for the diagnosis of adrenal dis
No
English
Adrenal Gland Diseases; Animals; Dog Diseases; Dogs; Female; Hydrocortisone; Immunoassay; Male; Reproducibility of Results
Settore VET/08 - Clinica Medica Veterinaria
Settore VET/10 - Clinica Ostetrica e Ginecologia Veterinaria
Articolo
Esperti anonimi
Pubblicazione scientifica
set-2009
38
3
332
336
5
Pubblicato
Periodico con rilevanza internazionale
crossref
pubmed
Aderisco
info:eu-repo/semantics/article
Comparison of the VIDAS and IMMULITE-2000 methods for cortisol measurement in canine serum / D. Proverbio, D. Groppetti, E. Spada, R. Perego. - In: VETERINARY CLINICAL PATHOLOGY. - ISSN 0275-6382. - 38:3(2009 Sep), pp. 332-336. [10.1111/j.1939-165X.2009.00135.x]
reserved
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
Periodico con Impact Factor
D. Proverbio, D. Groppetti, E. Spada, R. Perego
File in questo prodotto:
File Dimensione Formato  
Proverbio_et_al-2009-Veterinary_Clinical_Pathology.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 114.98 kB
Formato Adobe PDF
114.98 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/460744
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 16
social impact