IntroductionPatients on anticoagulant therapy with vitamin K antagonists (VKA) need frequent INR monitoring. Reliability of point-of-care (POC) devices for measuring INR needs rigorous evaluation, particularly in patient with the antiphospholipid syndrome (APS). The aim of this study was to evaluate the accuracy of the ProTime InRhythm System (here called device) for INR measurement in patients with APS on VKA. MethodsWe compared the device INR vs. the laboratory INR measurement for blood samples from 29 APS-positive and 31 APS-negative patients consecutively enrolled. APS was confirmed by positive serological and/or phospholipid-dependent coagulation tests. Chromogenic factor X assay was used to evaluate anticoagulation. Bland-Altman difference plot for paired INR (POC vs. laboratory) was used to evaluate agreement between the device and the laboratory. The device INR relationship with factor X chromogenic assay was evaluated by orthogonal regression analysis. ResultsOverall, 97% of the device INR measurements were similar to laboratory INR values with an absolute difference less than 0.4 units. Correlation coefficient for the device INR vs. factor X was -0.69 (P < 0.0001, CI 95% -0.80 to -0.52). ConclusionsThe ProTime InRhythm System is an accurate point-of-care device for measuring INR also in patients with and without APS.

Evaluation of a new PT-INR monitoring system in patients with the antiphospholipid syndrome / S. Braham, C. Novembrino, M. Moia, E. Torresani, A. Tripodi. - In: INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY. - ISSN 1751-553X. - 38:5(2016), pp. 497-504.

Evaluation of a new PT-INR monitoring system in patients with the antiphospholipid syndrome

A. Tripodi
Ultimo
2016

Abstract

IntroductionPatients on anticoagulant therapy with vitamin K antagonists (VKA) need frequent INR monitoring. Reliability of point-of-care (POC) devices for measuring INR needs rigorous evaluation, particularly in patient with the antiphospholipid syndrome (APS). The aim of this study was to evaluate the accuracy of the ProTime InRhythm System (here called device) for INR measurement in patients with APS on VKA. MethodsWe compared the device INR vs. the laboratory INR measurement for blood samples from 29 APS-positive and 31 APS-negative patients consecutively enrolled. APS was confirmed by positive serological and/or phospholipid-dependent coagulation tests. Chromogenic factor X assay was used to evaluate anticoagulation. Bland-Altman difference plot for paired INR (POC vs. laboratory) was used to evaluate agreement between the device and the laboratory. The device INR relationship with factor X chromogenic assay was evaluated by orthogonal regression analysis. ResultsOverall, 97% of the device INR measurements were similar to laboratory INR values with an absolute difference less than 0.4 units. Correlation coefficient for the device INR vs. factor X was -0.69 (P < 0.0001, CI 95% -0.80 to -0.52). ConclusionsThe ProTime InRhythm System is an accurate point-of-care device for measuring INR also in patients with and without APS.
Point-of-care; INR; anticoagulation; antiphospholipid antibodies; factor X
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
0381.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 345.6 kB
Formato Adobe PDF
345.6 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/454020
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact