We report a simple and rapid HPLC procedure for measuring p-aminohippuric acid in serum and urine. After deproteinization with acetonitrile and addition of p-aminobenzoic acid as an internal standard, the chromatographic run is performed on a C18 column with the absorbance detector set at 275 nm. The separation is carried out in 10 min at a flow-rate of 1.0 ml/min with a mobile phase composed of 7 mmol/l l-decanesulfonic acid, pH 3.70, and acetonitrile (82:18, v/v). The relationship between p-aminohippuric acid concentration and the p-aminohippuric acid/internal standard peak area is linear up to 100 μg/ml. Within-run precision measured at three different p-aminohippuric acid concentrations ranges from 1.73 to 1.98% in serum and from 0.72 to 1.32% in urine. Between-run precision varies from 1.80 to 3.06% in serum and from 1.05 to 2.66% in urine. Analytical recovery is between 98.26 and 99.44% in serum and from 99.57 to 100.45% in urine. The method is very simple, sensitive, and requires small volumes of sample for the assay (100 μl). Therefore, it could be a useful tool for the analysis of p-aminohippuric acid in the evaluation of renal plasma flow.

Rapid determination of p-aminohippuric acid in serum and urine by high-performance liquid chromatography / R. Marsilio, R. Dall'Amico, G. Montini, L. Murer, M. Ros, G. Zacchello, F. Zacchello. - In: JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL APPLICATIONS. - ISSN 1572-6495. - 704:1-2(1997 Dec), pp. 359-364.

Rapid determination of p-aminohippuric acid in serum and urine by high-performance liquid chromatography

G. Montini;
1997

Abstract

We report a simple and rapid HPLC procedure for measuring p-aminohippuric acid in serum and urine. After deproteinization with acetonitrile and addition of p-aminobenzoic acid as an internal standard, the chromatographic run is performed on a C18 column with the absorbance detector set at 275 nm. The separation is carried out in 10 min at a flow-rate of 1.0 ml/min with a mobile phase composed of 7 mmol/l l-decanesulfonic acid, pH 3.70, and acetonitrile (82:18, v/v). The relationship between p-aminohippuric acid concentration and the p-aminohippuric acid/internal standard peak area is linear up to 100 μg/ml. Within-run precision measured at three different p-aminohippuric acid concentrations ranges from 1.73 to 1.98% in serum and from 0.72 to 1.32% in urine. Between-run precision varies from 1.80 to 3.06% in serum and from 1.05 to 2.66% in urine. Analytical recovery is between 98.26 and 99.44% in serum and from 99.57 to 100.45% in urine. The method is very simple, sensitive, and requires small volumes of sample for the assay (100 μl). Therefore, it could be a useful tool for the analysis of p-aminohippuric acid in the evaluation of renal plasma flow.
p-aminohippuric acid
Settore MED/38 - Pediatria Generale e Specialistica
dic-1997
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/445028
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact