One of the main issue concerning the treatment of carotid artery stenosis is about the use of stents which could offer the best navigability through the lesion and the smallest "maximum unprotected circular area", ensuring the lowest risk of neurological complication both intraprocedurally and in the long term. Recently, Inspire MD (Tel Aviv, Israel) presented the new stent Inspire MD C-Guard™, a bare-metal stent covered by a micron level mesh (MicroNet). We report our experience about the use of this novel stent in the endovascular treatment of carotid artery stenosis, with some technical considerations. Data about patients in whom the Inspire MD C-Guard was used for the treatment of carotid artery diseases were retrospectively collected and analyzed. The procedure was completed in all patients without any intraoperative complications. Postoperative course was uneventful in all cases and no complications have been recorded till now. In our limited experience, the Inspire MD C-Guard has proven to be a safe stent for the treatment of carotid artery diseases. However large studies are needed to better explain strengths and weaknesses of this device.

Initial experience with the inspire MD C-Guard stent in the treatment of carotid artery disease / D. Mazzaccaro, M.T. Occhiuto, P. Righini, G. Malacrida, G. Nano. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - 57:3(2016 Jun), pp. 474-478.

Initial experience with the inspire MD C-Guard stent in the treatment of carotid artery disease

D. Mazzaccaro
Primo
;
G. Nano
Ultimo
2016

Abstract

One of the main issue concerning the treatment of carotid artery stenosis is about the use of stents which could offer the best navigability through the lesion and the smallest "maximum unprotected circular area", ensuring the lowest risk of neurological complication both intraprocedurally and in the long term. Recently, Inspire MD (Tel Aviv, Israel) presented the new stent Inspire MD C-Guard™, a bare-metal stent covered by a micron level mesh (MicroNet). We report our experience about the use of this novel stent in the endovascular treatment of carotid artery stenosis, with some technical considerations. Data about patients in whom the Inspire MD C-Guard was used for the treatment of carotid artery diseases were retrospectively collected and analyzed. The procedure was completed in all patients without any intraoperative complications. Postoperative course was uneventful in all cases and no complications have been recorded till now. In our limited experience, the Inspire MD C-Guard has proven to be a safe stent for the treatment of carotid artery diseases. However large studies are needed to better explain strengths and weaknesses of this device.
aged; aged, 80 and over; carotid stenosis; endovascular procedures; female; humans; male; prosthesis design; treatment outcome; stents
Settore MED/22 - Chirurgia Vascolare
giu-2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
Nano_JournalCardiovascularSurgery_Initial_2016.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.22 MB
Formato Adobe PDF
1.22 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/442919
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact