Objectives: The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). Methods: From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. Results: The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). Conclusions: MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. Key Points: • Cardiac computed tomographic coronary angiography (CCT) allows non-invasive evaluation of coronary arteries • Intra-cycle motion correction algorithm (MCA) allows for compensation of coronary motion • An MCA improves image quality, CCT evaluability and diagnostic accuracy

Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography / G. Pontone, D. Andreini, E. Bertella, A. Baggiano, S. Mushtaq, M. Loguercio, C. Segurini, E. Conte, V. Beltrama, A. Annoni, A. Formenti, M. Petullà, A.I. Guaricci, P. Montorsi, D. Trabattoni, A.L. Bartorelli, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 26:1(2016 Jan), pp. 147-156. [10.1007/s00330-015-3793-1]

Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography

G. Pontone
;
D. Andreini
Secondo
;
A. Baggiano;E. Conte;P. Montorsi;A.L. Bartorelli
Penultimo
;
2016

Abstract

Objectives: The aim of this study was to evaluate the impact of a novel intra-cycle motion correction algorithm (MCA) on overall evaluability and diagnostic accuracy of cardiac computed tomography coronary angiography (CCT). Methods: From a cohort of 900 consecutive patients referred for CCT for suspected coronary artery disease (CAD), we enrolled 160 (18 %) patients (mean age 65.3 ± 11.7 years, 101 male) with at least one coronary segment classified as non-evaluable for motion artefacts. The CCT data sets were evaluated using a standard reconstruction algorithm (SRA) and MCA and compared in terms of subjective image quality, evaluability and diagnostic accuracy. Results: The mean heart rate during the examination was 68.3 ± 9.4 bpm. The MCA showed a higher Likert score (3.1 ± 0.9 vs. 2.5 ± 1.1, p < 0.001) and evaluability (94%vs.79 %, p < 0.001) than the SRA. In a 45-patient subgroup studied by clinically indicated invasive coronary angiography, specificity, positive predictive value and accuracy were higher in MCA vs. SRA in segment-based and vessel-based models, respectively (87%vs.73 %, 50%vs.34 %, 85%vs.73 %, p < 0.001 and 62%vs.28 %, 66%vs.51 % and 75%vs.57 %, p < 0.001). In a patient-based model, MCA showed higher accuracy vs. SCA (93%vs.76 %, p < 0.05). Conclusions: MCA can significantly improve subjective image quality, overall evaluability and diagnostic accuracy of CCT. Key Points: • Cardiac computed tomographic coronary angiography (CCT) allows non-invasive evaluation of coronary arteries • Intra-cycle motion correction algorithm (MCA) allows for compensation of coronary motion • An MCA improves image quality, CCT evaluability and diagnostic accuracy
No
English
accuracy; cardiac computed tomography; coronary artery disease; intra-cycle motion correction algorithm; motion artefacts; aged; coronary angiography; coronary artery disease; coronary vessels; female; humans; male; motion; reproducibility of results; tomography, x-ray computed; algorithms; artifacts; radiology, nuclear medicine and imaging; medicine (all)
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
gen-2016
Springer
26
1
147
156
10
Pubblicato
Periodico con rilevanza internazionale
scopus
pubmed
crossref
Aderisco
info:eu-repo/semantics/article
Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography / G. Pontone, D. Andreini, E. Bertella, A. Baggiano, S. Mushtaq, M. Loguercio, C. Segurini, E. Conte, V. Beltrama, A. Annoni, A. Formenti, M. Petullà, A.I. Guaricci, P. Montorsi, D. Trabattoni, A.L. Bartorelli, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 26:1(2016 Jan), pp. 147-156. [10.1007/s00330-015-3793-1]
reserved
Prodotti della ricerca::01 - Articolo su periodico
17
262
Article (author)
no
G. Pontone, D. Andreini, E. Bertella, A. Baggiano, S. Mushtaq, M. Loguercio, C. Segurini, E. Conte, V. Beltrama, A. Annoni, A. Formenti, M. Petullà, A...espandi
File in questo prodotto:
File Dimensione Formato  
PontoneAndreini_EuropeanRadiology_Impact_2016.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 497.18 kB
Formato Adobe PDF
497.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/436750
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 43
  • OpenAlex 44
social impact