Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.
Computer-aided flapless implant surgery and immediate loading : A technical note / A. Baruffaldi, P.P. Poli, A. Baruffaldi, L. Giberti, M. Pigozzo, C. Maiorana. - In: ORAL AND MAXILLOFACIAL SURGERY. - ISSN 1865-1550. - 20:3(2016 Sep), pp. 313-319. [10.1007/s10006-016-0554-5]
Computer-aided flapless implant surgery and immediate loading : A technical note
P.P. Poli
;C. MaioranaUltimo
2016
Abstract
Purpose: The aim of the present technical note was to describe a prosthetic technique developed to increase the predictability of immediately loaded implants supporting a fixed prosthesis after computer-aided template-guided flapless implant placement. Methods: During a 2-year period, eight patients presenting partial edentulism underwent computer-aided template-guided implant placement. The presented technique was used during the prosthetic procedures to directly transfer the data obtained with the facebow to the surgical environment, allowing for accurate repositioning of the temporary prosthesis on the implants as previously planned with the digital software. Results: A total of 78 dental implants were immediately loaded with an implant-supported fixed prosthesis after flapless template-guided implant placement. A survival and success rate of 100 % was reported after a mean follow-up of 1 year from the prosthetic loading. Neither major complications nor dropouts were observed during the healing time. From both clinical and radiological evaluations, implants appeared stable with no signs of soft tissue inflammation or infection and no evidence of pathological peri-implant bone resorption. Conclusions: The proposed technique associated with computer-aided implant placement and immediate loading protocol provided a high implant and prosthetic survival and success rate. No complications were reported during the recalls, suggesting predictability and reliability of the present technique over a short-term period.File | Dimensione | Formato | |
---|---|---|---|
BaruffaldiMariorana_ComputerAided_MaxilloSurger_2016.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
2.03 MB
Formato
Adobe PDF
|
2.03 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.