A high-performance liquid chromatographic method for the determination of total plasma homocyst(e)ine [H(e)]after reduction with sodium tetrahydroborate and precolumn derivatization with o-phthaldialdehyde is described. The analyses, carried out on a reversed-phase C18 column, were based on spectrofluorimetric detection. The sensitivity was 1 pmol per injection and the intra- and inter-assay relative standard deviations were 1.8% and 5%, respectively. The plasma H(e) concentration determined in 40 healthy volunteers (20-60 years old) was 12.4±2.9 μM (mean±S.D.), in good agreement with reference values.

High-performance liquid chromatographic method with fluorescence detection for the determination of total homocyst(e)ine in plasma / I. Fermo, C. Arcelloni, E. De Vecchi, S. Vigano', R. Paroni. - In: JOURNAL OF CHROMATOGRAPHY. - ISSN 0021-9673. - 593:1-2(1992), pp. 171-176.

High-performance liquid chromatographic method with fluorescence detection for the determination of total homocyst(e)ine in plasma

R. Paroni
Ultimo
1992

Abstract

A high-performance liquid chromatographic method for the determination of total plasma homocyst(e)ine [H(e)]after reduction with sodium tetrahydroborate and precolumn derivatization with o-phthaldialdehyde is described. The analyses, carried out on a reversed-phase C18 column, were based on spectrofluorimetric detection. The sensitivity was 1 pmol per injection and the intra- and inter-assay relative standard deviations were 1.8% and 5%, respectively. The plasma H(e) concentration determined in 40 healthy volunteers (20-60 years old) was 12.4±2.9 μM (mean±S.D.), in good agreement with reference values.
No
English
coronary-artery disease; possible risk factor; total homocysteine; electrochemical detection; exchange chromatography; derivatization; urine; homocystinuria; deficiency; separation
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Articolo
Esperti anonimi
Ricerca applicata
Pubblicazione scientifica
1992
Elsevier
593
1-2
171
176
6
Pubblicato
Periodico con rilevanza internazionale
scopus
crossref
Aderisco
info:eu-repo/semantics/article
High-performance liquid chromatographic method with fluorescence detection for the determination of total homocyst(e)ine in plasma / I. Fermo, C. Arcelloni, E. De Vecchi, S. Vigano', R. Paroni. - In: JOURNAL OF CHROMATOGRAPHY. - ISSN 0021-9673. - 593:1-2(1992), pp. 171-176.
none
Prodotti della ricerca::01 - Articolo su periodico
5
262
Article (author)
no
I. Fermo, C. Arcelloni, E. De Vecchi, S. Vigano', R. Paroni
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/432504
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 57
  • ???jsp.display-item.citation.isi??? 55
social impact